Herunterladen Inhalt Inhalt Diese Seite drucken

Knick PolyTrans P32000P0/11-KTA Betriebsanleitung

Universall-meßumformer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Betriebsanleitung
Stratos®Pro
Bedienungsanleitung
Universal-Meßumformer. . . . . . . . . . . . .
Instructions for Use
Universal Transmitters . . . . . . . . . . . . .
Mode d'emploi
Convertisseurs universels . . . . . . . . . .
Aktuelle Produktinformation:
Aktuelle Produktinformation: www.knick.de
PolyTrans®
Stratos Pro A2... pH
deutsch
P32000P0/11-KTA
Betriebsanleitung
The Art of Measuring.
A2... PH
3
35
67
BVS 10 ATEX E089 X
II 1G Ex ia IIC T3/T4/T6
14163 Berlin
SE 706X/1-NMSN
BVS 10 ATEX E089 X
II 1G Ex ia IIC T3/T4/T
14163 Berlin
SE 706X/2-NMSN
BVS 10 ATEX E089 X
II 1G Ex ia IIC T3/T4/T
www.knick.de
14163 Berlin
SE 706X/2-NM
14163 Berlin
BVS 10 ATEX E
SE 706X/1-NM
II 1G Ex ia IIC
BVS 10 ATEX
II 1G Ex ia IIC
14163 Berlin
SE 706X/2-NM
BVS 10 ATEX
II 1G Ex ia IIC

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Knick PolyTrans P32000P0/11-KTA

  • Seite 1 Universal-Meßumformer... . . Instructions for Use Universal Transmitters ... . . Mode d‘emploi Convertisseurs universels ..www.knick.de Aktuelle Produktinformation: Aktuelle Produktinformation: www.knick.de...
  • Seite 3: Universal-Meßumformer

    P o ly T r a ns Universal Transmitter Power T ype P32000P0/11-KTA 0778440000000 ES03 Operat. T emp. 0 to +55 (65) °C DIP S1 = On www.knick.de Made in Germany SIL2 Functional Safety Type Approved ® Rheinland T Ü V www.knick.de...
  • Seite 4: Entsorgung

    Garantie Garantie Innerhalb von 5 Jahren ab Lieferung auftretende Mängel werden bei freier Anlieferung im Werk kostenlos behoben. Zubehör: 1 Jahr. Änderungen vorbehalten. Rücksendung Kontaktieren Sie das Service-Team, Kontaktdaten siehe Rückseite. Senden Sie das Gerät gereinigt an die Ihnen genannte Adresse. Entsorgung Die landesspezifischen gesetzlichen Vorschriften für die Entsorgung von “Elektro/Elektronik-Altgeräten”...
  • Seite 5: Inhaltsverzeichnis

    Inhaltsverzeichnis Garantie .................... 4 Sicherheitshinweise ............... 7 Bestimmungsgemäßer Gebrauch ..........8 Prinzipschaltbild ................... 8 Funktion ................... 9 3-Port-Trennung der Eingänge, Ausgänge und Stromversorgung ................. 9 Montage und elektrischer Anschluß ........10 Maßzeichnung und Schaltelemente ..........10 Meßbereiche .................11 Ausgangs nennbereich ..............11 Verhalten des Ausgangsstroms (4 ... 20 mA) bei Meßbereichsüber- bzw.
  • Seite 6 Inhaltsverzeichnis Technische Daten .................23 Eingangsdaten Widerstandsthermometer / Widerstand (RTD / R) ................23 Eingangsdaten Thermoelemente (TC) ........24 Eingangsdaten Potentiometer (Ratio)........25 Eingangsdaten Shuntspannung (Voltage) .......25 Eingangsdaten Dehnungsmeßstreifen (DMS) ......26 Ausgangsdaten ...................27 Übertragungsverhalten ..............28 Hilfsenergie ..................28 Isolation ....................28 Normen und Zulassungen ..............29 weitere Daten ..................30 Bestelldaten ...................31...
  • Seite 7: Sicherheitshinweise

    Sicherheitshinweise Warnung! Schutz gegen gefährliche Körperströme Bei Anwendungen mit hohen Arbeitsspannungen ist auf genügend Abstand bzw. Isolation zu Nebengeräten und auf Berührungsschutz zu achten. Achtung! Beim Umgang mit den Bausteinen ist auf Schutzmaßnah- men gegen elektrostatische Entladung (ESD) zu achten. Achtung! Die Universal-Meßumformer PolyTrans®...
  • Seite 8: Bestimmungsgemäßer Gebrauch

    Bestimmungsgemäßer Gebrauch Die Universal-Meßumformer PolyTrans® P 32000 bieten Anschlußmög- lichkeiten für alle gängigen Thermoelemente, Widerstandsthermome- ter, DMS-Vollbrücken, Widerstände, Potentiometer und Widerstands- meßfühler. Bei Widerstandsmeßfühlern wird die Anschlußkonfiguration 2-, 3- oder 4-Leiterschaltung beim Gerätestart automatisch erkannt. Das Ausgangssignal ist einstellbar auf 0 / 4 ... 20 mA oder 0 ... 5 / 10 V. Die Umschaltung der Meßbereiche erfolgt kalibriert über DIP- und Drehcodierschalter.
  • Seite 9: Funktion

    Funktion Der Universal-Meßumformer tastet Signale von Thermoelementen, Wi- derstandsthermometern, Dehnungsmeßstreifen, Widerstandsmeßfüh- lern etc. periodisch ab und formt den Abtastwert in ein dem Meßwert proportionales Ausgangssignal um. Das Ausgangssignal kann als Spannungs- oder Stromsignal ausgege- ben werden. Eine 3-Port-Trennung mit sicherer Trennung nach EN 61140 bis zu 300 VAC/DC garantiert Personen- und Anlagenschutz sowie eine unverfälschte Übertragung der Meßsignale.
  • Seite 10: Montage Und Elektrischer Anschluß

    Montage und elektrischer Anschluß Die Meßumformer werden auf TS 35 Normschienen aufgerastet und seitlich durch geeignete Endwinkel fixiert. Klemmenbelegung siehe Maßzeichnung. Anschlußquerschnitt: 0,2 mm ... 2,5 mm (AWG 24-14). Maßzeichnung und Schaltelemente Bedienöffnung für Taster Betriebs-LED (grün) Status-LED (gelb) Melde-LED (rot) Taster Eingang 1 + Startwert (2 Drehcodierschalter)
  • Seite 11: Meßbereiche

    Meßbereiche Der Meßumformer kann das Eingangssignal in ein Strom- oder Span- nungssignal umwandeln („Ausgangsnennbereich“): 0 ... 5 V 0 ... 10 V 0 ... 20 mA 4 ... 20 mA Dabei wird der eingestellte Start-Wert des Meßbereichs (siehe S. 18) auf den Anfang des Ausgangsnennbereichs und der End-Wert auf das Ende des Ausgangsnennbereichs abgebildet.
  • Seite 12: Verhalten Des Ausgangsstroms (4

    Meßbereiche Verhalten des Ausgangsstroms (4 ... 20 mA) bei Meßbereichsüber- bzw. -unterschreitung...
  • Seite 13: Beschaltungsvarianten (Sensoranschluß)

    Beschaltungsvarianten (Sensoranschluß) PolyTrans P32000P0/11-KTA Einstellbar über: Sensor Anschluß Abbildung IrDA Schal- 0 ... 5kOhm 2-, 3- oder 4-Leiter, 1, 2, 3 oder fest eingestellt 5 .. 100 kOhm 0 ... 5kOhm 2-, 3- oder 4-Leiter, 1, 2, 3 oder automatische Erkennung 5 ..
  • Seite 14: Anschluß Von Widerstandsthermometern / Widerstandsgebern

    Beschaltungsvarianten Anschluß von Widerstandsthermometern / Widerstandsgebern RTD/ Widerstand: RTD/ Widerstand: RTD/ Widerstand: 4-Leiter 3-Leiter 2-Leiter: (bei 2-Leiter- Messung mit R > 5kΩ ist eine Brücke zwischen Klemme 1 und Klemme 2 zu setzen) Potentiometer: Potentiometer: 3-Leiter 4-Leiter Ratio = Ratio = Mit Hilfe der Software Paraly SW 111 kann der volle Funktionsumfang des Meßumformers parametriert werden.
  • Seite 15: Anschluß Von Widerstandsthermometern / Thermoelementen

    Beschaltungsvarianten Anschluß von Widerstandsthermometern / Thermoelementen RTD Differenz: Differenz Diff Diff Ext. Kaltstellen- TC Summen- kompensation schaltung Pt 100 Mit Hilfe der Software Paraly SW 111 kann der volle Funktionsumfang des Meßumformers parametriert werden. Beschaltungsbeispiele mit grau hinterlegter Abbildungsnummer sind nur über IrDA einstellbar.
  • Seite 16: Anschluß Bei Spannungsmessung

    Beschaltungsvarianten Anschluß bei Spannungsmessung Spannung Shunt Anschluß bei Dehnungsmeßstreifen-Brücken (DMS) Diff Diff externe Speisung (1 ... 3 V) Klemme 1: Brückenspeisespannung (+) Klemme 1: Fühlerleitung (+) Klemme 4: Brückenspeisespannung (-) Klemme 4: Fühlerleitung (-) Klemme 2: Meßsignal (+) Klemme 2: Meßsignal (+) Klemme 3: Meßsignal (-) Klemme 3: Meßsignal (-) Mit Hilfe der Software Paraly SW 111 kann der volle Funktionsumfang des Meßumformers parametriert...
  • Seite 17: Anschluß Thermoelement (Summenschaltung)

    Beschaltungsvarianten Anschluß Thermoelement (Summenschaltung) TC Summenschaltung Hinweis: In Summenschaltung können maximal 10 Thermoelemente ange- schlossen werden. Mit Hilfe der Software Paraly SW 111 kann der volle Funktionsumfang des Meßumformers parametriert werden. Beschaltungsbeispiele mit grau hinterlegter Abbildungsnummer sind nur über IrDA einstellbar.
  • Seite 18: Konfigurierung Über Schalter

    Konfigurierung über Schalter Stellen Sie die DIP- und Drehcodierschalter gemäß Tabelle (Gehäuse- aufdruck) ein. Sensortyp: Angeschlossenen Sensor über Schalter DIP1 bis DIP3 einstellen. Startwert: Stellen Sie den Ziffernwert (00 ... 99) mit Hilfe der Drehkodierschalter „Start“ ein. Über die Schalter DIP4, DIP5 stellen Sie den Faktor ein. Eine fallende Kennlinie wird durch die Einstellung Startwert größer Endwert realisiert.
  • Seite 19: Kommunikation Über Irda-Schnittstelle

    Parameter des Meßumformers (siehe Tabelle auf Seite 13). Die Softwa- re wird mit einer detaillierten Anleitung ausgeliefert, welche auch als Download auf der Website „www.knick.de“ zur Verfügung steht. Erweiterte Funktionsmerkmale des Universal-Meßumformers durch Kommunikation über die Software „Paraly SW 111“:...
  • Seite 20: Konfigurierung Über Schalter: Funktionsübersicht

    Konfigurierung über Schalter: Funktionsübersicht = DIP-Schalter ON...
  • Seite 21: Konfigurierung Über Schalter: Beispiel

    Faktor x10+1000 einstellen: DIP6 = 1 4. Ausgangssignal einstellen: 4 ... 20 mA: DIP7 = 0, DIP8 = 1 Hinweis: Unter www.knick.de/Polytrans finden Sie eine Einstellhilfe, Menüpunkt: „Intuitive Programmierung“ Achtung! Nach erfolgter Konfigurie- rung müssen Sie die Schalter mit der beiliegenden selbst- klebenden Polyimid-Folie abdecken.
  • Seite 22: Led Und Fehlersignalisierung Am Gerät

    LED und Fehlersignalisierung am Gerät Hinweis: Grüne und rote LED blinken beim Gerätestart kurz auf. grün: Versorgungsspannung vorhanden gelb: Beim Start einmalige Signalisierung der erkannten Anschlußart bei RTD-Messung (2-/3-/4-maliges Blinken entspricht 2-/3-/4-Leitermessung) Blinken: IrDA aktiv Dauerlicht: IrDA verbunden rot: Fehlerstatus; die LED blinkt mit der Anzahl der Fehlernummer Ausgang [mA] Ausgang [V] Fehler...
  • Seite 23: Technische Daten

    Technische Daten Eingangsdaten Widerstandsthermometer / Widerstand (RTD / R) Gebertyp (Norm) Meßbereich [°C] Pt100 (DIN 60751) - 200 ... 850 Pt1000 (DIN 60751) - 200 ... 850 Ptxxx (DIN 60751) - 200 ... 850 Ni100 (DIN 43760) - 60 ... 180 Nixxx (DIN 43760) - 60 ...
  • Seite 24: Eingangsdaten Thermoelemente (Tc)

    Technische Daten Eingangsdaten Thermoelemente (TC) Gebertyp (Norm) Meßbereich [°C] nur über IrDA wählbar (DIN 60584-1) 250 ... 1820 (DIN 60584-1) - 200 ... 1000 (DIN 60584-1) - 210 ... 1200 (DIN 60584-1) - 200 ... 1372 (DIN 43710) - 200 ... 900 (DIN 60584-1) - 200 ...
  • Seite 25: Eingangsdaten Potentiometer (Ratio)

    Technische Daten Eingangsdaten Potentiometer (Ratio) Eingang 200 Ω ... 50 kΩ Anschluß 3- oder 4-Leiter (4-Ltr. nur über IRDA) Speisestrom 0 ... 5 mA Leitungsüberwachung Leitungsbruch Eingangsfehlergrenzen ± (0,2 % v.E. +0,05 % v.M.) für Meß- spannen > 5 % Temperaturkoeffizient am 50 ppm/K vom konfigurierten Meß- Eingang...
  • Seite 26: Eingangsdaten Dehnungsmeßstreifen (Dms)

    Technische Daten Eingangsdaten Dehnungsmeßstreifen (DMS) Eingang - 7,5 mV/V ... 7,5 mV/V Brückenwiderstand 200 Ω ... 10 kΩ Nullpunktabgleich innerhalb des Eingangsbereiches Speisestrom (int. Speisung) 0 ... 5 mA Speisespannung für T ≤ 55 °C: 1 ... 3 V (externe Speisung) für T >...
  • Seite 27: Ausgangsdaten

    Technische Daten Ausgangsdaten Ausgänge 0 ... 20 mA, 4 ... 20 mA, 0 ... 10 V oder 0 ... 5 V, kalibriert umschaltbar Aussteuerbereich 0 % bis ca. 102,5 % der Meßspanne bei 0 ... 20 mA, 0 ... 10 V bzw. 0 ...
  • Seite 28: Übertragungsverhalten

    Technische Daten Übertragungsverhalten Kennlinie Linear steigend / fallend; über IrDA: parametrierbare Kennlinie mit Stütz- stellen oder über Polynome Meßrate ca. 3 / s ca. 2 / s im Betriebsmodus Thermoelement mit ext. Vergleichs- stellenkompensation bzw. Widerstandsmessung 5 k ... 100 kOhm Einstellzeit t 99* 300 ms 500 ms im Betriebsmodus Thermoelement mit ext.
  • Seite 29: Normen Und Zulassungen

    Technische Daten Schutz gegen gefährliche Sichere Trennung nach DIN EN 61140 (VDE 0140 Teil 1) durch verstärkte Isolie- Körperströme rung gemäß DIN EN 61010-1 (VDE 0411 Teil 1). Arbeitsspannung bis zu 300 V AC/ DC bei Überspannungskategorie II und Verschmutzungsgrad 2 zwischen allen Kreisen.
  • Seite 30: Weitere Daten

    Technische Daten weitere Daten Umgebungstemperatur bei Betrieb 0 ... + 65 °C Einzelgerät mit Abstand > 6 mm zu Nachbargeräten 0 ... + 55 °C (angereihter Zustand; Die Geräte werden unter Verwendung der Zwischenstücke ZU0784 montiert) bei Lagerung - 25 ... + 85 °C Umgebungsbedingungen Ortsfester Einsatz, wettergeschützt rel. Luftfeuchte 5 ... 95 %, keine Betauung Luftdruck: 70 ...
  • Seite 31: Bestelldaten

    Bestelldaten Bestellnr. Universal-Meßumformer, einstellbar P32000P0/11-KTA Zubehör Bestellnr. ® Kommunikations-Software Paraly SW 111 SW111...
  • Seite 35 P o ly T r a ns Universal Transmitter Power T ype P32000P0/11-KTA 0778440000000 ES03 Operat. T emp. 0 to +55 (65) °C DIP S1 = On www.knick.de Made in Germany SIL2 Functional Safety Type Approved ® Rheinland T Ü V www.knick.de...
  • Seite 36: Warranty

    Warranty Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our plant (carriage and insurance paid by sender). Accessories: 1 year. Subject to change without notice. Return of products Please contact our Service Team before returning a defective device (see back cover for contact details).
  • Seite 37 Table of Contents Warranty ..................36 Safety Information ...............39 Intended Use .................40 Block diagram ..................40 Function ..................41 3-port isolation of inputs, outputs and power supply ..41 Mounting and Electrical Connection ........42 Dimension drawing and control elements.......42 Measuring Ranges ................43 Nominal output range ..............43 Response of output current (4 ...
  • Seite 38 Table of Contents Specifications ................55 Input data for resistance thermometer / resistor (RTD / R) ................55 Input data for thermocouple (TC) ..........56 Input data for potentiometer (ratio) ...........57 Input data for shunt (voltage) ............57 Input data for strain gage ...............58 Output data..................59 Response ....................60 Power supply ..................60...
  • Seite 39: Safety Information

    Safety Information Warning! Protection against electric shock For applications with high working voltages, ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks. Caution! Be sure to take protective measures against electrostatic discharge (ESD) when handling the devices! Caution! P32000P0/11-KTA The PolyTrans®...
  • Seite 40: Intended Use

    Intended Use The PolyTrans® P 32000 universal transmitters provide connection possibilities for all standard thermocouples, resistance thermometers, strain gage full bridges, resistors, potentiometers and resistive sensors. When a resistive sensor is connected, 2-, 3-, or 4-wire configuration is automatically recognized at device startup. The output signal is adjustable to 0 / 4 ...
  • Seite 41: Function

    Function The universal transmitter periodically samples signals from thermo- couples, resistance thermometers, strain gages, resistive sensors, etc. These signals are converted into output signals proportional to the measured values. The output signal can be a voltage or a current. 3-port isolation with Safe Isolation up to 300 V AC/DC according to EN 61140 ensures optimum protection of personnel and equipment as well as unaltered transmission of measuring signals.
  • Seite 42: Mounting And Electrical Connection

    Mounting and Electrical Connection The transmitters are snapped onto TS 35 standard rails and laterally fixed by suitable end brackets. See dimension drawing for terminal as- signments. Conductor cross-section: 0.2 mm ... 2.5 mm (AWG 24-14). Dimension drawing and control elements Hole for pushbutton Operation LED (green) Status LED (yellow)
  • Seite 43: Measuring Ranges

    Measuring Ranges The transmitter can convert the input signal into a current or voltage signal ("nominal output range"): 0 ... 5 V 0 ... 10 V 0 ... 20 mA 4 ... 20 mA The start value adjusted for the measuring range (see Pg 50) is repre- sented by the lower limit of the nominal output range.
  • Seite 44: Response Of Output Current (4

    Measuring Ranges Response of output current (4 ... 20 mA) to out-of-range conditions 21.0 20.5 Input Start value End value...
  • Seite 45: Wiring Possibilities (Sensor Connection)

    Wiring Possibilities (Sensor Connection) PolyTrans P32000P0/11-KTA Adjustable via: Sensor Type Connection Figure IrDA Switch 0 ... 5kohms 2-, 3- or 4-wire, 1, 2, 3 fixed setting 5 ... 100 kohms 0 ... 5kohms 2-, 3- or 4-wire, 1, 2, 3 automatic recognition 5 ...
  • Seite 46: Wiring Possibilities

    Wiring Possibilities Connection of resistance thermometers / resistance transducers RTD/Resistor: RTD/Resistor: RTD/Resistor: 4-wire 3-wire 2-wire: (For 2-wire measurement with R > 5kΩ, place jumper across terminal 1 and terminal 2) Potentiometer: Potentiometer: 3-wire 4-wire Ratio = Ratio = You can configure all functions of the transmitter using the Paraly SW 111 software. Wirings with a shaded number can only be adjusted via IrDA.
  • Seite 47 Wiring Possibilities Connection of resistance thermometers / thermocouples RTD difference: difference: Diff Diff Ext. cold junction TC summing compensation configuration Pt 100 You can configure all functions of the transmitter using the Paraly SW 111 software. Wirings with a shaded number can only be adjusted via IrDA.
  • Seite 48: Connection For Voltage Measurement

    Wiring Possibilities Connection for voltage measurement Voltage Shunt Connection for strain gage bridges Diff Diff Strain gage Strain gage External supply (1 ... 3 V) Terminal 1: Bridge supply voltage (+) Terminal 1: Sense line (+) Terminal 4: Bridge supply voltage (-) Terminal 4: Sense line (-) Terminal 2: Measured signal (+) Terminal 2: Measured signal (+)
  • Seite 49: Connection Of Thermocouple (Summing Configuration)

    Wiring Possibilities Connection of thermocouple (summing configuration) TC summing configuration Please note: You can only connect up to 10 thermocouples in summing configuration. You can configure all functions of the transmitter using the Paraly SW 111 software. Wirings with a shaded number can only be adjusted via IrDA.
  • Seite 50: Configuration Using Switches

    Configuration using Switches Adjust the DIP and rotary switches according to the table on the housing. Sensor type: Select the connected sensor type using switches DIP1 to DIP3. Start value: Adjust the number (00 ... 99) using the "Start“ rotary switches. Adjust the factor using the switches DIP4, DIP5.
  • Seite 51: Communication Via Irda Interface

    PC or PDA. It allows configuring all transmitter parameters (see table on Pg 45). The software comes with detailed instructions which are also available for download at "www.knick.de". Additional functions of the universal transmitter when using "Paraly SW 111" software:...
  • Seite 52: Configuration Using Switches: Overview Of Functions

    Configuration using Switches: Overview of Functions = DIP switch ON...
  • Seite 53: Configuration Using Switches: Example

    DIP6 = 1 4. Adjust output signal: 4 ... 20 mA: DIP7 = 0, DIP8 = 1 Please note: You find an adjustment aid at www.knick.de/Polytrans: "Intuitive Adjustment“ Caution! After completion of con- figuration you must cover the switches with the included...
  • Seite 54: Leds And Error Signaling On Device

    LEDs and Error Signaling on Device Note: Green and red LEDs flash momentarily at device startup. Green: Supply voltage provided Yellow: For RTD measurement, the identified connection type is signaled once at the start (2/3/4-time blinking corresponds to 2/3/4-wire measurement) Blinking: IrDA active Constant light: IrDA connected...
  • Seite 55: Specifications

    Specifications Input data for resistance thermometer / resistor (RTD / R) Sensor type (Standard) Range [°C] Pt100 (DIN 60751) -200 ... 850 Pt1000 (DIN 60751) -200 ... 850 Ptxxx (DIN 60751) -200 ... 850 Ni100 (DIN 43760) - 60 ... 180 Nixxx (DIN 43760) - 60 ...
  • Seite 56: Input Data For Thermocouple (Tc)

    Specifications Input data for thermocouple (TC) Sensor (Standard) Range [°C] Selectable via type IrDA only (DIN 60584-1) 250 ... 1820 (DIN 60584-1) -200 ... 1000 (DIN 60584-1) -210 ... 1200 (DIN 60584-1) -200 ... 1372 (DIN 43710) -200 ... 900 (DIN 60584-1) -200 ...
  • Seite 57: Input Data For Potentiometer (Ratio)

    Specifications Input data for potentiometer (ratio) Input 200 Ω ... 50 kΩ Connection 3- or 4-wire (4-wire via IRDA only) Supply current 0 ... 5 mA Line monitoring Open circuits Input error limits < (0.2% full scale +0.05% meas.val.) for spans > 5% Temperature coefficient 50 ppm/K of adjusted end value at input...
  • Seite 58: Input Data For Strain Gage

    Specifications Input data for strain gage Input -7.5 mV/V ... 7.5 mV/V Bridge resistance 200 Ω ... 10 kΩ Zero adjustment Within input range Supply current (int. supply) 0 ... 5 mA Supply voltage for T ≤ 55 °C: 1 ... 3 V (external supply) for T >...
  • Seite 59: Output Data

    Specifications Output data Outputs 0 ... 20 mA, 4 ... 20 mA, 0 ... 10 V or 0 ... 5 V, Calibrated switching Control range 0% to approx. 102.5% span for 0 ... 20 mA, 0 ... 10 V or 0 ...
  • Seite 60: Response

    Specifications Response Characteristic Rising / falling linearly; via IrDA: curve defined by sampling points or polynomials Measuring rate Approx. 3 / s Approx. 2 / s in operating mode: thermocouple with ext. reference junction compensation or resistance measurement 5 k ... 100 kohms Response time t 99* 300 ms 500 ms in operating mode:...
  • Seite 61: Standards And Approvals

    Specifications Protection against Safe Isolation to EN 61140 by reinforced insulation according to EN 61010-1. electric shock Working voltage up to 300 V AC/DC across all circuits with overvoltage cat- egory II and pollution degree 2. For applications with high working volt- ages, ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks.
  • Seite 62: Other Data

    Specifications Other data Ambient temperature during operation 0 ... +65 °C single unit with > 6 mm spacing to adjacent devices 0 ... +55 °C (mounted in row) The devices are mounted using ZU0784 spacers) during storage -25 ... +85 °C Ambient conditions Stationary application, weather-protected Relative air humidity 5 ...
  • Seite 63: Order Information

    Order Information Type Order No. Universal transmitters, adjustable P32000P0/11-KTA Accessories Order No. Paraly® SW 111 communication software SW111...
  • Seite 67 P o ly T r a ns Universal Transmitter Power T ype P32000P0/11-KTA 0778440000000 ES03 Operat. T emp. 0 to +55 (65) °C DIP S1 = On www.knick.de Made in Germany SIL2 Functional Safety Type Approved ® Rheinland T Ü V www.knick.de...
  • Seite 68: Garantie

    Garantie Garantie Tout défaut constaté dans les 5 ans à dater de la livraison sera réparé gratuitement à réception franco de l'appareil. Accessoires : 1 an. Sous réserve de modifications. Retour Contactez le service après-vente, les coordonnées se trouvent au dos. Envoyez l'appareil après l'avoir nettoyé...
  • Seite 69 Table des matières Garantie ......................68 Consignes de sécurité ..................71 Utilisation conforme ..................72 Schéma de principe ....................72 Fonction ......................73 Isolation 3 ports des entrées, des sorties et de l'alimentation ....73 Montage et raccordement électrique ............74 Dessin coté et éléments de commande ............74 Plages de mesure .....................
  • Seite 70 Table des matières Caractéristiques techniques ................87 Données d'entrée Thermomètre à résistance / Résistance (RTD / R) ....................87 Données d'entrée Thermocouples (TC) ............88 Données d'entrée Potentiomètre (ratio) ............89 Données d'entrée Tension de shunt (voltage) ..........89 Données d'entrée Jauge de contrainte ............90 Données de sortie ....................91 Caractéristique de transmission .................92 Alimentation auxiliaire ...................92...
  • Seite 71: Consignes De Sécurité

    Consignes de sécurité Avertissement ! Protection contre les chocs électriques En cas d’utilisation avec des tensions de service élevées, veiller à avoir une distance ou une isolation suffisante par rapport aux appareils voisins et respecter la protection aux contacts. Attention ! Lors de la manipulation des composants, appliquer des mesures de protection contre les décharges électrostatiques (ESD).
  • Seite 72: Utilisation Conforme

    Utilisation conforme Les convertisseurs universels PolyTrans® P 32000 offrent des possibilités de raccordement pour tous les thermocouples, thermomètres à résistance, jauges de contrainte en pont complet, résistances, potentiomètres et sondes résistives. Pour les sondes résistives, la configuration de raccordement 2, 3 ou 4 fils est détectée automatiquement au démarrage de l'appareil.
  • Seite 73: Fonction

    Fonction Le convertisseur universel balaie régulièrement les signaux des thermo- couples, des thermomètres à résistance, des jauges de contrainte, des sondes résistives, etc., et convertit la valeur balayée en un signal de sortie proportionnel à la valeur de mesure. Le signal de sortie peut être émis sous forme de signal de tension ou sous forme de signal de courant.
  • Seite 74: Montage Et Raccordement Électrique

    Montage et raccordement électrique Les convertisseurs sont clipsés sur les rails normalisés TS 35 et fixés latérale- ment par une équerre d'embout appropriée. Pour le brochage, voir le dessin coté. Section de raccordement : 0,2 mm ... 2,5 mm (AWG 24-14). Dessin coté...
  • Seite 75: Plages De Mesure

    Plages de mesure Le convertisseur peut convertir le signal d'entrée en un signal de courant ou de tension (“plage nominale de sortie”) : 0 ... 5 V 0 ... 10 V 0 ... 20 mA 4 ... 20 mA La valeur initiale de la plage de mesure réglée (cf. p. 82) est alors représentée au début de la plage nominale de sortie et la valeur finale est représentée à...
  • Seite 76: Comportement Du Courant De Sortie (4

    Plages de mesure Comportement du courant de sortie (4 ... 20 mA) en cas de dépassement positif ou négatif de la plage de mesure 21,0 20,5 Entrée Valeur initiale Valeur finale...
  • Seite 77: Variantes De Connexion (Raccordement Du Capteur)

    Variantes de connexion (raccordement du capteur) PolyTrans P32000P0/11-KTA Réglage : Capteur Type Raccord Figure IrDA Com- muta- teur 0 ... 5kΩ 2, 3 ou 4 fils, 1, 2, 3 réglage fixe 5 ... 100 kΩ 0 ... 5kΩ 2, 3 ou 4 fils, 1, 2, 3 détection automatique...
  • Seite 78 Variantes de connexion Raccordement des thermomètres à résistance et des convertisseurs à résistance RTD/Résistance : RTD/Résistance : RTD/Résistance : 4 fils 3 fils 2 fils (pour la mesure à 2 fils avec R > 5kΩ, un shunt doit être placé entre la borne 1 et la borne 2) Potentiomètre :...
  • Seite 79 Variantes de connexion Raccordement des thermomètres à résistance et des thermocouples Différence TC : Différence RTD : Diff Diff Compensation de soudure froide ext. Circuit de connexion Pt 100 additionneur Il est possible de programmer toutes les fonctions du convertisseur à l'aide du logiciel Paraly SW 111. Les exemples de connexion pourvus d'un numéro de figure grisé...
  • Seite 80: Raccordement Pour La Mesure De La Tension

    Variantes de connexion Raccordement pour la mesure de la tension Tension Shunt Raccordement pour des jauges de contrainte en pont complet Diff Diff Jauge de contrainte Jauge de contrainte Alimentation externe (1 ... 3 V) Borne 1 : Tension d'alimentation du pont (+) Borne 1 : Fil de capteur (+) Borne 4 : Tension d'alimentation du pont (-) Borne 4 : Fil de capteur (-)
  • Seite 81: Raccordement Du Thermocouple (Circuit De Connexion Additionneur)

    Variantes de connexion Raccordement du thermocouple (circuit de connexion additionneur) Circuit de connexion additionneur Remarque : Dans un circuit de connexion additionneur, 10 thermocouples peuvent être raccordés au maximum Il est possible de programmer toutes les fonctions du convertisseur à l'aide du logiciel Paraly SW 111. Les exemples de connexion pourvus d'un numéro de figure grisé...
  • Seite 82: Configuration Via Les Commutateurs

    Configuration via les commutateurs Réglez les commutateurs DIP et les commutateurs rotatifs selon le tableau marqué sur le boîtier. Type de capteur : Régler le capteur raccordé avec les commutateurs DIP1 à DIP3. Valeur initiale : Programmez la valeur chiffrée (00 à 99) à l'aide des commutateurs rotatifs “Start”.
  • Seite 83: Communication Via L'interface Irda

    (cf. tableau sur la page 77). Le logiciel est livré avec une notice d'utilisation détaillée, qui peut aussi être téléchargée sur le site Internet “www.knick.de”. Caractéristiques de fonctionnement étendues du convertisseur universel par communication avec le logiciel “Paraly SW 111” :...
  • Seite 84: Configuration Via Les Commutateurs : Aperçu Des Fonctions

    Configuration via les commutateurs : aperçu des fonctions = Commutateur DIP ON...
  • Seite 85: Configuration Via Les Commutateurs : Exemple

    4. Programmer le signal de sortie : 4 ... 20 mA : DIP7 = 0, DIP8 = 1 Remarque : Vous trouverez à l'adresse www.knick.de/ Polytrans une aide à la programmation, point de menu : “Intuitive Adjustment“ (Programmation intuitive) Attention ! Une fois la configuration correc- tement effectuée, vous devez...
  • Seite 86: Led Et Signalisation Des Erreurs Sur L'appareil

    LED et signalisation des erreurs sur l'appareil Remarque : Les LED rouge et verte clignotent brièvement au démarrage de l'appareil. vert : tension d'alimentation présente jaune : au démarrage, une seule indication du type de raccordement détecté pour la mesure RTD (un clignotement répété...
  • Seite 87: Caractéristiques Techniques

    Caractéristiques techniques Données d'entrée Thermomètre à résistance / Résistance (RTD / R) Type de (Norme) Plage de mesure [°C] capteur Pt100 (DIN 60751) - 200 ... 850 Pt1000 (DIN 60751) - 200 ... 850 Ptxxx (DIN 60751) - 200 ... 850 Ni100 (DIN 43760) - 60 ...
  • Seite 88: Données D'entrée Thermocouples (Tc)

    Caractéristiques techniques Données d'entrée Thermocouples (TC) Type de (Norme) Plage de mesure [°C] sélectionnable capteur uniquement via l'IrDA (DIN 60584-1) 250 ... 1820 (DIN 60584-1) - 200 ... 1000 (DIN 60584-1) - 210 ... 1200 (DIN 60584-1) - 200 ... 1372 (DIN 43710) - 200 ...
  • Seite 89: Données D'entrée Potentiomètre (Ratio)

    Caractéristiques techniques Données d'entrée Potentiomètre (ratio) Entrée ... 50 k Ω Ω Raccord 3 ou 4 fils (4 fils uniquement via l'IRDA) Courant d'alimentation 0 ... 5 mA Surveillance de ligne Rupture de câble Limites d'erreur en entrée ± (0,2 % de la val. finale +0,05 % de la val. mes.) pour des fourchettes >...
  • Seite 90: Données D'entrée Jauge De Contrainte

    Caractéristiques techniques Données d'entrée Jauge de contrainte Entrée - 7,5 mV/V ... 7,5 mV/V Résistance de pont ... 10 k Ω Ω Compensation du zéro dans la plage d'entrée Courant d'alimentation 0 ... 5 mA (alimentation interne) Tension d'alimentation pour T ≤ 55 °C : 1 ... 3 V (alimentation externe) pour T >...
  • Seite 91: Données De Sortie

    Caractéristiques techniques Données de sortie Sorties 0 ... 20 mA, 4 ... 20 mA, 0 ... 10 V ou 0 ... 5 V, calibrée commutable Plage utile 0 % jusqu'à env. 102,5 % de la fourchette pour 0 ... 20 mA, 0 ... 10 V ou 0 ...
  • Seite 92: Caractéristique De Transmission

    Caractéristiques techniques Caractéristique de transmission Courbe caractéristique Linéaire montante/descendante ; via IrDA : paramétrable avec points d'appui par IrDA ou par polynôme Cadence de mesure env. 3 / s env. 2 / s dans le mode de fonctionne- ment : thermocouple avec compensa- tion externe des points de comparaison mesure de résistance 5 k ... 100 kΩ...
  • Seite 93: Normes Et Homologations

    Caractéristiques techniques Protection contre les Séparation sûre suivant EN 61140 par chocs électriques isolation renforcée suivant EN 61010-1. Tension de service jusqu'à 300 V CA/CC pour la catégorie de surtension II et le degré de pollution 2 entre tous les circuits. Dans le cas des applications avec des tensions de service élevées, observer une distance suffisante ou assurer une isola-...
  • Seite 94: Autres Caractéristiques

    Caractéristiques techniques Autres caractéristiques Température ambiante en fonctionnement 0 ... + 65 °C (chaque appareil distant de > 6 mm des appareils voisins) 0 ... + 55 °C (disposition en série ; Les appareils sont montés à l'aide des raccords ZU0784) en stockage - 25 ... + 85 °C Conditions environnantes Utilisation fixe sur site, à...
  • Seite 95: Références

    Références Type N° de cde Convertisseur universel réglable P32000P0/11-KTA Accessoires N° de cde ® Logiciel de communication Paraly SW 111 SW111...
  • Seite 100 Knick Elektronische Messgeräte GmbH & Co. KG Beuckestr. 22 14163 Berlin Germany Phone: +49 (0)30 - 801 91 - 0 Fax: +49 (0)30 - 801 91 - 200 Email: knick@knick.de Web: www.knick.de 080489 TA-254.111-KNX04 20140116...

Inhaltsverzeichnis