Herunterladen Inhalt Inhalt Diese Seite drucken

patura MaxiBox P 250 Bedienungsanleitung Seite 54

Vorschau ausblenden Andere Handbücher für MaxiBox P 250:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
Mounting Instructions
A battery-only installation has unique requirements. Regular recharging of the battery is
essential. Use a suitably-rated battery charger to recharge the battery. Refer to the battery
manufacturer's recommendations.
1. Disconnect the battery from the energizer.
2. A ttach the positive (+) battery charger lead to the positive terminal of the battery, and the
negative (–) battery charger lead to the negative terminal on the battery.
3. I nsert the battery charger's input power plug into a mains or line socket and turn on the
power supply.
4 A fter the battery is charged, disconnect it from the battery charger before connecting it to
the energizer.
Over-charging the battery will reduce its life. Do not exceed the
recommendations of the battery manufacturer on recharging the
battery from a mains-powered (line-powered) source.
A correctly installed solar energizer system requires very little battery maintenance. The solar
panel selected should be sufficient to maintain the battery at full or near-full charge.
Battery care and maintenance
• H ouse the battery in a suitably designed battery box, if the battery is likely to be exposed to
the weather.
• W hen not in use, store the battery fully charged and recharge at regular intervals
(every 8 weeks).
• R echarge a discharged battery as soon as possible. Batteries should not be left discharged.
• I nspect the battery regularly to ensure that the electrolyte level does not fall below the
surface of the battery plates.
• T op up the battery using distilled water. Do not overfill. Refer to the battery manufacturer's
recommendations for more information.
Battery safety
• Ensure that the battery is well ventilated when recharging.
• Avoid temperatures greater than 50 °C (120 °F).
• Ensure that the battery is not exposed to a naked flame or sparks.
In all switch positions, the energizer will stop functioning before the
!
!
battery discharges completely. This helps to prevent battery damage.
Battery protection
To ensure the battery remains in good condition, the energizer will automatically turn off once
the battery is flat. The energizer will restart once the battery has been recharged or replaced.
54

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis