Herunterladen Inhalt Inhalt Diese Seite drucken

Schou 547705 Gebrauchsanweisung Seite 73

Terrassenheizer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 87
Construction and characteristics
Transportable terrace/garden heater with tank housing
Casing in steel with powder-coating or stainless steel
Gas hose connections with metal clamp (screw caps for Germany)
Heat emission from refl ector
Specifi cations
Use propane, butane or their mixtures gas only.
Max. wattage: 13000 watts Min. wattage: 5000 watts
APPLIANCE
CATEGORY:
TYPES OF GAS:
GAS PRESSURE:
OUTLET
PRESSURE OF
REGULATOR:
Using the proper regulator according to outlet pressure of regulator as showed in the table
above.
Table of injector
APPLIANCE
CATEGORY:
TYPES OF GAS:
GAS PRESSURE:
TOTAL HEAT
INPUT (Hs): (Qn)
INJECTOR SIZE:
The marking for example 1.90 on the injector indicates that the size of injector is 1.90mm
The hose and regulator assembly must conform to local standard codes.
Regulator outlet pressure should meet the corresponding gas category in the table of injector.
The appliance requires approved hose in 1.2 m length.
I3+(28-30/37)
Butane
Propane
28-30mbar
37 mbar
30mbar
37 mbar
I3+(28-30/37)
Butane
Propane
28-30mbar
37 mbar
13kW (G30:945g/h; G31:929g/h)
1.90 mm for main burner
0.18 mm for pilot burner
Consumption: 456-870 g/h
I3B/P(30)
I3B/P(50)
Butane, propane or their mixtures
30 mbar
50mbar
30 mbar
50mbar
I3B/P(30)
I3B/P(50)
Butane, propane or their mixtures
30 mbar
50mbar
1.70 mm for
main burner
0.18 mm for
pilot burner
GB
I3B/P(37)
37mbar
37mbar
I3B/P(37)
37mbar
1.80 mm for
main burner
0.18 mm for
pilot burner