Important
If you want to remove the charger from the battery, it's important that the
charging process is always completely finished. As such, the charging process
should only be stopped when the green LED lights or blinks. If the charging process
is interrupted before it is completed, the battery loses its charge and its acid
balance.
When disconnecting the battery or at interruption of the mains voltage, the
current charging process will stop. When a battery is re-connected or the
mains voltage is present again, in both cases a new charging process will start.
When a problem is detected at the start or during the charge process, then an
'E' and the number of the relevant error will appear alternately in the display.
Consult the 'Charge Status' and 'Trouble Shooting' for the right actions.

CHARGE STATUS

The charging process can be followed by means of the red, yellow and green
LED. If an error occurs during the charging process an error message will be
displayed on the display.
Boost
Equalize
Compensate
Float
Jogging
Reverse polarisation or
no battery present
Battery Voltage too
low
14 hour limit
Temperature
protection
Battery sulphated
Temp.sensor error
Consult "Trouble shooting" for the error messages.
25
'charge process'
Yellow LED
Red
LED
lights
blinks
X
X
Green LED
lights
blinks
X
X
Display
Error
code
X
E 1
E 2
E 3
E 4
E 5
E 6