Commissioning

The pump control is activated or deactivated directly at the base station, or with an Alpha IP room
control unit Display.

6.4.1 Activation/deactivation of the pump control (base station)

1.
Press the Select key (B) of the Alpha IP base station approximately for 4 seconds, until the LED of
heating zone 1 flashes in green:
Duration in seconds
0,1
0,2
0
HZ1
Duration in seconds
0,5
1,0
0
HZ1
2.
Toggling the pump from active to inactive or vice versa: Press the Select key (B) for 4 seconds.
3.
Leaving the menu without changes: Press the Select key shortly.

6.4.2 Activation/deactivation of the pump control (Room control unit Display)

With the Alpha IP room control unit Display, different parameters can be assigned to the pump con-
trol. For this, the parameter P025 in menu UnP1 (see „Configuration" page 29) must be changed
according to the requirements.
For parametrisation, one Alpha IP room control unit must have been taught in to heating
zone 1. This device can be used for further heating zones.
7 Commissioning
For the commissioning of the Alpha IP base station, at least one Alpha IP room control unit Display,
Display S or Analog must be taught-in to the base station. As an alternative, the base station can be
integrated to the Alpha IP Access Point via the app into the Alpha IP system. If used without Access
Point, the base station must be configured via the Alpha IP room control unit Display.
1.
Establish the electrical supply of the Alpha IP base station.
9 All heating zones of the base station are activated for 10 minutes in order to unlock the first-open
function of connected actuators.
9 A 2-point regulation is performed in the first 30 minutes after the initial voltage supply.
2.
Proceed with section 7.1 or 7.2 depending on the system configuration.

7.1 Teach-in without Alpha IP Access Point (stand-alone operation)

Keep a minimum distance of 50 cm between the devices for teaching-in.
26
All manuals and user guides at all-guides.com
Display
0,3
0,4
1,5
2,0
Meaning
Pump inactive
(UnP1: P025, value 4)
Pump active
(UnP1: P025, value 0)