Technical Maintenance - THERMEx ID 30 V Gebrauchsanweisung

Elektrischer warmwasserspeicher
Vorschau ausblenden Andere Handbücher für ID 30 V:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 61
EN
For control from a mobile device water heater has Wi-Fi function.
ы
Install app "Thermex Home" from GooglePlay or AppStore. Create an ac-
1.
count.
2.
On water heater panel press and hold buttons 2 and 3 together (Fig. 2). Appears
Wi-Fi indication (cl. 10, Fig. 2).
In application "Thermex Home":
3.
click Add Device
from the drop list, select Water Heater
next follow the instructions of application.
Failures:
make sure Wi-Fi function is enabled on your mobile device
make sure you are connected to the Internet
or contact your provider.
When performing maintenance scale on THE is checked. At the same time residue
that may accumulate in the bottom of the EWH is removed. If there is scale on THE, it
can be removed by using scale removing means or mechanically. It is recommended to
hold the first technical maintenance after a year from the time of connection by experts
of a specialized organization and depending on intensity of scale and residue to deter-
mine intervals of follow-up maintenance. This action will extend the maximum EWH
service life.
ATTENTION: accumulation of scale on TEH may cause its damage .
Note: Damages to THE due to scale formation are not subject to warranty. Regular
maintenance is not included in the warranty of the manufacturer and the seller.
The following shall be carried out for maintenance:
sending the other end down the drain;
the hose;
from the casing the removable flange;
8

11. TECHNICAL MAINTENANCE

Turn off EWH power;
Cool hot water or discharge it through the mixer;
Cut off supply of cold water into EWH;
Unscrew the relief valve or open drain valve;
To put on the cold water supply inlet or discharge valve a rubber hose,
Open hot water tap on mixer and drain water from the EWH through
Remove the protective cover, disconnect wires, unscrew and remove
Clean if necessary THEs from scale and remove residue from the tank;
Assemble, fill the EWH with water and power on.