Herunterladen Inhalt Inhalt Diese Seite drucken

Cosmo WILO PARA STG 15/7-50 Montage- Und Betriebsanleitung Seite 87

2-strang solarstation dn 20
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

om_para__4533597_01__2002_de_en_fr.book Seite 43 Montag, 10. Februar 2020 3:43 15
Wilo-Connector
connection
Connection to an
existing device
Installation and operating instructions Wilo-Para
Installing Wilo-Connector
• Disconnect the connecting cable from the power
supply.
• Observe terminal assignment (
• Connect and install the Wilo-Connector
(Fig. 5a to 5e).
Connecting the pump
• Earth the pump.
• Connect the Wilo-Connector to the connection
cable until it snaps into place (Fig. 5f).
Removing the Wilo-Connector
• Disconnect the connecting cable from the power
supply.
• Remove the Wilo-Connector using a suitable
screwdriver (Fig. 6).
The pump can be directly connected to an existing pump
cable with a 3-pin plug (e.g. Molex) when being replaced
(Fig. 3, item a).
• Disconnect the connecting cable from the
power supply.
• Press down the locking button of the installed plug
and remove the plug from the control module.
• Observe the terminal assignment (PE, N, L).
• Connect the existing device plug to the plug
connection (12) of the control module.
;
(PE), N, L ).