Table with parameters
Parameter code Description
Parameter Menu CP
diF
Temperature step width
HSE
Set maximum temperature
LSE
Set minimum temperature
HC
Control mode (H = heat; C = cool)
If the temperature sensor fails, the compressor is shifted to the cycle
mode:
Ont
On t: Runtime for the switched-on phase
OF t: Runtime for the switched-off phase of the cycle.
Ont=0;OFt=1: Compressor remains off.
OFt
Ont=1;OFt=0: Compressor is permanently on.
Ont≠0;Ont≠0: Compressor runs in the cycle
with the times for the switched-on and -off phases as described above.
dOn
Delay time until the compressor starts
dOF
Time interval between the
dbi
The time interval between two consecutive comp. start processes
OdO
Time delay of the output after the device switches on
Parameter Menu diS
LOC
Button lock (n = buttons not blocked, y = buttons locked)
It is possible to program the parameters further
PA1
User password
ndt
Display the decimal point: y = yes; n = no
CA1
Calibrate temperature
dro
Temperature unit (0 = °C, 1 = °F)
Parameter Menu CnF
H00
Selection of the sensor type (0 = PTC, 1 = NTC)
rEL
Device version
tAb
Parameter overview
The target value [SEt] should always be between the parameters [LSE] (lowest target value to be set) and [HSE] (highest target value to be set). For example, if [HSE] is set to 10, the
target value cannot be set higher.
All manuals and user guides at all-guides.com
Value range
"1 - 30"
"LSE - 99"
"-55 - HSE"
"H/C"
On t: Runtime for the switched-on phase of the cycle. 0
"0-250"
"0-250"
"0-250"
"0-250"
"0-250"
"n/Y"
"0-250"
"n/Y"
"-12-12"
"0/1"
"0/1"
"/"
"/"

Factory setting

Unit
2
°C/°F
99
°C/°F
-55
°C/°F
H
/
Minutes
1
Minutes
0
Seconds
0
Minutes
0
Minutes
0
Minutes
n
/
0
/
n
/
0
°C/°F
1
/
1
/
/
/
/
/