thank you for choosing this Campingaz
heater.
this operating handbook is common to the following
appliances:
CR 5000
CR 5000 Thermo
CR 5000 Turbo

A - GENERAL SAFETY INSTRUCTIONS

- This appliance must be used and serviced in accordance
with the regulations and standards in force.
- Please read this handbook before using your
GB
appliance.
-This appliance should not be used in high rise flats,
in basements, bathrooms or bedrooms.
- Only use this appliance in a well ventilated room.
- This appliance should not be used in leisure
vehicles such as caravans and camping-cars.
- This appliance should not be installed in the vicinity
of walls, pieces of furniture, hangings, curtains,
bedding items and other inflammable materials. To
prevent fire hazards, it is strictly forbidden to cover
the appliance.
- This appliance should always be directed to the
centre of the room.
- Do not use your heater less than 50 cm from a wall
or combustible object.
- Do not cover or block the holes of the air intake
positioned at the bottom, front or top of the appliance.
- Do not use the appliance without having fitted the
wheels. The use of the device without wheels can
be dangerous for people.
- The gas hose should be replaced when the expiry
date is passed or whenever it is damaged or
develops surface cracks.
B - ASSEMBLING THE WHEELS
it is compulsory to fit the 4 wheels on the bottom
of the device before using the appliance. Use a
spanner 13 (see fig. 1).
C - SETTING TO SERVICE
IMPORTANT
this operating handbook is intended for enabling
you to correctly and safely use your Campingaz
appliance.
refer to the handbook to familiarise yourself with
the appliance before connecting the gas bottle.
Comply with this operating handbook instructions.
this appliance must be connected using a pressure
reducing valve and a hose. Call your vendor.
Non conformance with these instructions may be
dangerous for the user and his environment.
Permanently keep this handbook in a safe place so
as to refer to it when needed.
this appliance is preset in factory to operate with
butane using appropriate pressure reducing valve
and hose.
in operation, this appliance must be held away from
inflammable materials.
do not use a leaking, malfunctioning or damaged
appliance. return it to your vendor who will give
you the address of the nearest dealer.
this appliance should never be modified nor used
in applications for which it is not designed.
C - 1 - Ventilating the room:
this appliance is a catalytic combustion heater
designed to be used in a sufficiently ventilated room.
a suitable ventilation makes it possible to exhaust
combustion residues and renew the combustion air.
the appliance should not be installed in a room the
catalytic
®
volume of which is less than 61 m
30.5 m
air renewal ventilation area should not be less than
77 cm² evenly distributed between room upper and
lower levels.
a safety device will shut off the gas, thus extinguishing
the appliance if normal ventilation conditions are not
met.
C - 2 - Gas bottle and pressure reducing valve:
this appliance is designed to operate with 11 Kg
to 15 Kg Butane or Propane gas bottles fitted with
an adequate pressure reducing valve (See Gas and
operating pressures page 3).
only use the type of gas stipulated by the manufacturer.
In France, Belgium, Great Britain and Ireland it
is strictly forbidden to use another gas type than
Butane.
to install the pressure reducing valve, follow pressure
reducing valve operating handbook instructions.
to connect or replace the bottle, always operate in a
well-ventilated place, never in presence of a flame,
spark or heat source.
C - 3 - Gas hose:
France:
the appliance must be used with a hose fitted with a G
1/2 threaded nut to be screwed to the appliance and an
M 20x1.5 threaded nut to be screwed to the pressure
reducing valve (XP d 36-112 Standard).
the hose shall be 0.50 m long. it shall be replaced if
it appears to be damaged or cracked. do not pull or
twist the hose. Keep it away from parts that are likely
to get heated.
Hose installation, G 1/2 and M 20x1.5 nuts (XP
D 36-112 Standard) (See Fig. 2 and 3):
G 1/2
appliance
- Check tightness in compliance with indications of
®
paragraph d-2.
Switzerland, Germany, Austria:
this appliance must be used with a diN hose the
quality of which shall comply with the use of butane or
propane gas.
the hose shall be 0.50 m long. it shall be replaced if
it appears to be damaged or cracked. do not pull or
twist the hose. Keep it away from parts that are likely
to get heated.
Connecting the hose: to connect the hose to appliance
inlet union, firmly but moderately tighten the hose using
2 suitable spanners:
- 14 mm spanner to tighten appliance inlet union.
- 17 mm spanner to screw in hose nut.
Connect the other end to pressure reducing valve
outlet union.
- Check tightness in compliance with indications of
paragraph d-2.
Other countries:
the appliance is fitted with a ringed end-piece. il must
be used with a hose the quality of which shall comply
with the use of butane or propane gas and with the
8
for other rooms.
3
for living-rooms and
3
M 20x1,5
Pressure
black
reducing valve

Werbung