2
Description
25
26
27
23
Connection XS 8 I/O Port
Connection option for additional peripheral units.
One input and one output for each channel, additionally two high-speed
outputs, see section 7.2.5 "XS 8 I/O Port".
24
Connection XS 5 RS232
Serial interface for connection of a programmable logic controller (PLC) or a
PC for data readout or for firmware updating.
Connect via 9 pin Sub D cable (1:1). Only pins 2, 3 and 5 must be assigned.
Observe the serial interface protocol.
9600 baud/1stop bit/no parity/8 data bits.
25
Connection XS 3 Dispense monitor
Connector for a Pre-Amplifier 97211, for flow monitoring on channel A. A
second pre-amplifier for channel B can be connected with splitter cable 97529.
Calorimetric dispense monitoring requires only one Pre-Amplifier 97512.
Unlike pressure based monitoring systems, this pre-amplifier can be used for
monitoring
2 dispense valves.
26
Connection XS 10 PLC
Parallel interface for connection of a programmable logic controller.
Per dispense channel, two output signals each are available for "Ready" and
"Error", and two input signals for "Start" and "Reset"; additional signals for
"Refill" and "Empty" provided from product supply (reservoir).
27
Connection XS 2 Product reservoir
Is used to connect the product reservoir. Only one reservoir can be actuated.
24
23
61