Description
12 13
12
12
Button: Setup and Manual mode
Without preselected channel, for the following settings:
– Language setting,
– Channel setting,
– Factory settings,
– Setup of dispense program change, and
– Checking of input and output signals.
With preselected channel, the adjustments for setup mode can be made, such
as dispensing valve On or Off.
Caution!
All adjustment and setup operations in the MANUAL OPERATION directory
must be performed by authorized personnel only!
13
Button: Start
After channel preselection a complete dispense cycle can be started, e. g. in
manual mode. Without channel preselection, Channel A is automatically switched
to active mode.
14
Button: Prime
With preselected channel, is used for priming the feed line of the selected
channel or opening the selected dispense valve as long as the key is
depressed. This step proceeds independent of the adjusted dispense time. If
this key is pressed without preselecting a channel, Channel A will be
automatically switched to active mode.
15
Button: Reservoir
Key for reservoir pressurization/depressurization. Reservoir
pressurization/depressurization is actuated only as long as the key is
depressed. The reservoir will be depressurized automatically after low level
signaling. For pressurization, the hand lever valve on the product reservoir
must be set to ON or Pressurize.
14 15
14
59