2. Safety Warnings

2.1. General instructions

Signs used to mark instructions in this manual
Safety instructions in these operating instructions,
which, if not observed, could cause a danger for persons
are marked with the general symbol in accordance with DIN
4844-W 9.
Warnings against electrical voltage are marked with the
safety symbol in accordance with DIN 4844-W 8.

2.2. General Safety Precautions

General regulations and guidelines not mentioned in the
safety warnings retain their validity.
These operating instructions contain basic instructions,
which have to be adhered to during installation, operation
and maintenance. These operating instructions must be
read from mechanic and the operator before installation and
operation of the pump and have to be kept available at the
operating place of the machine/unit at all times. Persons
who are not familiar with the operating instructions shall not
use this product.
Children and adolescents under age 16 shall not use
the pump and must keep away from the machine/unit
while it is operational.
The unit must be installed from a technical experienced
plumber.
The working area has to be closed off expediently and
must adhere to local workplace regulations.
Always use personal safety equipment such as safety
boots, rubber gloves, safety glasses and helmet.
Make sure that the emergency exit from the workplace
is not barricaded.
To prevent suffocation and poisoning caused by ven-
omous gases, make sure that enough oxygen exists at the
workplace.
Never work alone at the unit.
Make sure that required aids like lifting ramp is in a
regular and reliable condition.
If you have to work with welding tools or electric tools,
make sure that there is no explosion hazard.
Immediately after repair or maintenance work, all safety
and protection equipment must be reinstalled and placed in
function again.
The operator of the pump is responsible for third parties
within the work area.
Never put a hand or finger into suction inlet or dis-
charge of the pump while the impeller is rotating.
All other rules and regulations and local codes covering
health and safety must be observed. In accordance with
product liability law, we point out that we shall not be liable
for damages caused by the pump due to non-observance of
the instructions and guidelines set forth in the operating in-
structions. The same product liability are
valid for accessories.
All manuals and user guides at all-guides.com

3. Applications and Technical Description

3.1. Applications

HOMA disposal unit Sanipower is used for pumping drain-
age water, waste water and sewage from rooms which are
below the sewer level.
The unit dispose sanitary installations like WC, hand basins,
washing machines and showers. With the advantage of a
ground level direct WC connection, it is possible to place
the unit directly on the back of the toilet.

3.2. Product description

Odour and gas-tight collection tank with a single stage cen-
trifual pump. The tank has a horizontal WC-inlet, a
vertical inlet on the top of the tank, a vertical air vent
and a clening cover.
The disposal unit Sanipower is equipped with a cutter sys-
tem at the pump inlet which cuts all soft solids to small par-
ticles, so that the liquid may be pumped through small di-
ameter discharge pipes of 1 ¼" Ø.
The disposal unit has equipped a pneumatic level control
with pressure switch.

3.3. Technical Data

Motor input P
Motor output P
Voltage
Nominal current
Speed
Insulation class
Degree of protection
Controller
Motor
Cable length
Cable type
Discharge
Utility volume
Weight
3.4. Operating Conditions
Maximum liquid temperature: 35°C, short term up to
60°C.
Density of pumped liquid: max. 1100 kg/m
Ph-value of pumped liquid: 5 up to 11.
Operation: The motor is designed for continuous operation
(S1) with fully submerged motor, maximum 15 starts per
hour. Our standard warranty and maintenance regulations
refer to intermittent operation. For reduced warranty
periods and service intervals due to continuous operating
4conditions please contact our service department.
3.5. Explosive Environments
only models with explosion-proof motors (Ex model) must
be used.
tion (Ex-class) of the pump must be approved by the loca-
lauthorities.

4. Warranty

Our warranty only covers pumps which are installed and
operated in accordance with these installation and operation
instructions and accepted codes of good practice and being
used for the applications mentioned in these instructions.
10
1
2
For operation of the pumps in explosive environments
For each individual installation the explosion classifica-
1,5 kW
1,1 kW
230 V/50Hz
7,0 A
2900 U/min
H
IP 54
IP 68
2,0 m
H07RN-F4G1,5
BSP 2" M
11 l
32 kg
3