Herunterladen Diese Seite drucken

KEUCO IXMO 59511 011100 Gebrauchsanleitung Seite 10

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
EN
Malfunction / Cause / Remedy
Error
Water doesn't fl ow
Water runs
continuously and stops
when an object is in
the detection zone!
Water doesn't stop
fl owing!
Water starts fl owing on
its own!
Fitting leaky, water
leaks out!
Temperature cannot be
properly adjusted!
10
Important information, please make sure to read!
Symptom
Water supply cut off
Aerator clogged/dirty
Filter clogged/dirty at solenoid valve
Solenoid valve defective
Mixing cartridge clogged/defective
Flow pressure too low
Cable plug-connector between battery
compartment and sensor washbasin mixer
severed
Connection cable kinked or broken
No battery power available
Cleaning mode active
Sensor detection zone not properly adjusted
Sensor window scratched/dirty
Interfering refl ections from washbasin
Polarity of plug between electronic module
and solenoid valve reversed
Sensor detection zone set too small
Solenoid valve defective
Interfering objects in detection zone
Continuous water fl ow active
Flow pressure too high
Sensor window scratched/dirty
Sensor washbasin mixer is aff ected by
infl uences from the room (mirror, metal
surfaces, glass washbasin, etc.)
Defective gaskets or incorrect installation
Water drips from spout, solenoid not closing
properly
Too little or no hot or cold water
Filter clogged/dirty in water supply
Water temperature too low or too high
Water temperature too low or too high (mixed
water temperature cartridge)
Remedy
Turn on water supply
Clean or replace aerator
Clean or replace solenoid valve
Replace solenoid valve
Contact KEUCO customer service
Increase fl ow pressure
Establish cable plug-connection
Replace defective cable and component
Check battery, replace as necessary
Wait until end of cleaning mode
Adjust detection zone
Carefully clean sensor window
Adjust detection zone
Connect plug connection properly
Increase size of sensor detection zone
Replace solenoid valve
Remove objects from detection zone
Cancel continuous water fl ow, or wait
Check fl ow pressure, set to 0.5 - 5.0 bar
Carefully clean sensor window
Decrease size of detection zone
Check installation and replace defective
gaskets as necessary
Clean or replace solenoid valve as necessary
Open the angle valve completely
Clean or replace fi lter
Check temperature of water supply and adjust
as necessary
Adjust temperature with lever

Werbung

loading

Diese Anleitung auch für:

Ixmo 59512 011100