If there is scale in the water bath, wipe the bath with soft cloth dipped with cleaning agent, and rinse
off with water.
•External cleaning of the humidifier
Rinse the soft cloth in warm water of below 40℃, wipe off the surface stain. The spray nozzle can be
flushed with water directly.
•Storage of humidifier
When the unit is net to be used for a long time, clean and dry the unit, store it at a dry place in the
original package.

Common Troubleshooting Method

Abnormal symptom
Indicator not illuminated, no
air, no fog
Indicator illuminated with
air, no fog
Spray with odor
Indicator illuminated no air
,no fog
Small fog output

Disposal of old electrical appliances

The European directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE), requires
that old household electrical appliances must not be disposed of in the normal unsorted municipal
waste stream. Old appliances must be collected separately in order to optimize the
recovery and recycling of the materials they contain, and reduce the impact on
human health and the environment. The crossed out "wheeled bin" symbol on the
product reminds you of your obligation, that when you dispose of the appliance, it
must be separately collected. Consumers should contact their local authority or
retailer for information concerning the correct disposal of their old appliance.
Cause
The power plug is not
properly plugged.
The power switch is not
turned on.
There is no water in the
water tank
The automatic constant
humidity knob is not turned
on
The water level float cap is
not held down
New unit
The water in the tank is not
clean
The water level in the water
bath is too high
There is scale formation on
the transducer
The water is dirty or has
been stored too long
Handling
Plug the power plug properly
Turn in the power switch
Top up the water tank
Turn the automatic constant
humidity knob clockwise
Hold down the water level
float cap.
Open the water tank
Place at a shade for 12 hours
Clean or replace the water
tank
Pour out some water in the
water bath
Screw down the water tank
cover
Clean the transducer
Replace with clean water