Herunterladen Inhalt Inhalt Diese Seite drucken

FAMOS Roto Sealer F 220-Serie Bedienungshandbuch Seite 49

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Standard screen
Input screen
System
The below-mentioned option 1 t/m 0 all belong to the system menu
1)Temperature
2) Date/Time
3) Seal parameters
4) Service menu
99.900.121 rev.:1
All manuals and user guides at all-guides.com
Will be displayed after the set temperature has been reached.
Input is possible through this screen of:
7) Expiry date 1 or 2,
8) Textno. 1
9) Textno. 2
10) Code.
Next to that one can go to the following menu's
11) Label printing
For input of quantity and type of labels used.
12) System.
Via a PIN-code "2345" one go into the system menu
Setting the temperature
Setting the time / clock (24-hour system).
Setting the date and the structure of the date how it will be displayed
and printed.
1=DMY=day,month,year
2=YMD=year,month,day
3=MDY=month,day,year
Display of the last recorded seal parameters on the LCD-display.
In the service menu the following data is displayed
-
Counter signal of the last performed maintenance,
-
the current counter signal and
-
counter signal for the next planned maintenance.
With the option "Next maintenance " one can set the counter signal at
a counter position at which the next maintenance should be taken
place.
With the option "Calibration" the stored and pre-set seal parameter
accuracy can be set. This option is only available for qualified
personnel only to avoid falls settings of those parameter pre-settings.
49

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Roto sealer f220dep

Inhaltsverzeichnis