Installation Planning, Con't.
DANGER:
Failure to use a Vented Loop in raw water pump
!
installation sites can lead to water fl owing into the toilet from the
outside (siphoning) which can cause loss of property and life!
Required Tools
■
1-1/4" hole saw
■
1 3/4" - 2" hole saw
■
3-1/2" hole saw
■
7/16" socket and ratchet or 7/16" wrench
■
Electric drill
■
1/8" drill bit
Bezel Installation
When planning the installation be sure to
consider:
■ Bezel placement wall thickness
■
Distance between toilet and bezel; the harness is 12' in length
DANGER
HAZARD OF FIRE:
!
mended circuit breakers or fuses. Failure to follow the recommendations
can result in fi re.
Fig. F
Tecma EasyFit Owner's & Installation Manual
Always use recom-
Bezel Specifi cations / Abmessungen der Blende
73 mm
56 mm
Planung des Einbaus (Fortsetzung)
GEFAHR:
Wenn bei Installationen mit Seewasserpumpe kein
!
belüftbares Schwanenhalsventil verwendet wird, kann Wasser (durch
Siphonwirkung) von außen in die Toilette gesaugt werden, was zu
Sachschäden und zum Verlust von Menschenleben führen kann!
Erforderliche Werkzeuge
■
32 mm Lochsäge
■
45 mm - 51 mm Lochsäge
■
9 cm Lochsäge
■
11 mm Steckschlüssel und Ratsche oder 11 mm
Schraubenschlüssel
■
Elektrobohrmaschine
■
3 mm Bohrer
Installation der Blende
Bei der Planung des Einbaus ist Folgendes zu
berücksichtigen:
■
Wandstärke am Anbringungsort der Blende
■
Abstand zwischen Toilette und Blende (der Kabelbaum ist 3,7 m
lang)
GEFAHR
BRANDGEFAHR:
!
Sicherungsautomaten oder Sicherungen verwenden, um Brände zu
vermeiden.
Abb. F
64 mm
46 mm
Bezel Hole Size
Größe der Blendenöffnung
6
Stets die empfohlenen
44 mm - 51 mm
www.thetford.com