Herunterladen Inhalt Inhalt Diese Seite drucken

Ul Approval; Indicators; Read Operation (Basic Setting) - IFM Electronic efector190 DTS125 Montageanleitung

Rf-identifikationssystem
Vorschau ausblenden Andere Handbücher für efector190 DTS125:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6.3

UL approval

The following note applies to the units DTA20x and DTA30x only.
The device shall be supplied from an isolating transformer having a secondary
Listed fuse rated either
a) max 5 amps for voltages 0...20 V
b) 100/V
for voltages of 20...30 V
p
7

Indicators

1:
green (operating voltage)
2:
yellow (ID tag)
3:
red (AS-i data communication)
7.1

Read operation (basic setting)

LED
Status
green
ON
OFF
yellow
ON (pulse)
ON (permanently)
OFF
red
ON
OFF
All manuals and user guides at all-guides.com
(0...28.3 V
rms
(28.3...42.4 V
rms
Description
operating voltage OK
operating voltage missing
ID tag read successfully
ID tag read successfully and still in the field
no ID tag in the field
or faulty ID tag in the field
or invalid ID tag in the field
error AS-i data communication
AS-i data communication OK
) or
p
).
p
UK
19