Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance & Servicing; Spares And Accessories - Cole Parmer Stuart SI505 Bedienungsanweisung

Microtitre plate shaker incubator
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Setting the timer
18. Press the mode button until a red dot shows in the
display below "time". The display will show three
horizontal lines or the last set time.
19. For continuous operation, set the display to the three
horizontal lines.
20. Select the required countdown time by turning the
control knob. The time will be displayed first in
minutes and seconds, next in hours and minutes,
then in days and hours up to a maximum of 9 days.
21. If the platform is already in motion, countdown will
start immediately. Otherwise, press the start/stop
button to begin countdown; motion will also start at
the set speed.
22. During operation, motion and countdown can
be paused at any time by pressing the start/
stop button. Press the start/stop button again to
continue.
23. The timer can be adjusted at any time without
halting the unit by turning the control knob.
24. When the timer reaches zero, the unit will
automatically stop motion and an alert will sound.
Note: If the door is opened while the unit is in motion a
warning alert will sound and the motion and countdown
will stop. The word "door" will also be momentarily
displayed on the screen. The heater will remain ON. Close
the door to continue and the countdown will resume
from the point at which it was stopped.
USB connectivity
The SI505 has capability to connect to a PC via USB
for long term tracking of the incubator chamber
temperature.
25. First, download the latest version of the SI505
software from www.stuart-equipment.com. Once
downloaded, follow the installation instructions.
26. Remove the waterproof cap from the USB port on the
side of the SI505 and connect the included cable.
27. Connect the other end of the cable to a free USB port
on a PC.
28. Follow the software instructions for new hardware
installation.
29. Click 'Run Software' to complete the program start-
up.
Maintenance & Servicing
WARNING: Ensure the unit is disconnected from the
mains electricity supply before attempting maintenance
or servicing.
Periodically clean the instrument using a damp cloth and
mild detergent solution. Do not use harsh or abrasive
cleaning agents.
Any repairs or replacement of parts MUST be
undertaken by suitably qualified personnel.
For a comprehensive list of parts required by service
engineers conducting internal repairs, please contact the
Service Department, quoting both the model number
and serial number:
E-mail: cpservice@coleparmer.com
Tel: +44 (0)1785 810475
Only spare parts supplied or specified by Stuart or its
agents should be used. Fitting of non-approved parts
may affect the performance of the safety features
designed into the instrument. If in any doubt, please
contact the Service Department of Cole Parmer Ltd. or the
point of sale.
For any other technical enquiries, please contact the
Technical Support Department:
E-mail: cptechsupport@coleparmer.com
Tel: +44 (0)1785 810433.

Spares and Accessories

Description
Tube holder for 1.5ml tubes
Tube holder for 0.5ml tubes
Tube holder for 0.2ml tubes
Warranty
Stuart warrants this equipment to be free from defects in
material and workmanship, when used under normal
laboratory conditions, for a period of three (3) years. In
the event of a justified claim, Stuart will replace any
defective component or replace the unit free of charge.
This warranty does NOT apply if damage is caused by
fire, accident, misuse, neglect, incorrect adjustment or
repair, damage caused by installation, adaptation,
modification, fitting of non-approved parts or repair by
unauthorised personnel.
Cole-Parmer Ltd.
Beacon Road, Stone,
Staffordshire , ST15 0SA
United Kingdom
Tel: +44 (0) 1785 812121
E-mail: cpinfo@coleparmer.com
www.stuart-equipment.com
Catalogue Number
SSM5/1
SSM5/2
SSM5/3

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis