INSTALLATION POSSIBILITIES:

Minimum distances:
When installing the distances as in the following sketches must be met.
Vertical installation:
- The minimum distance from the upper edge of the radiator to the cabin ceiling must be at least 7 cm (see fig. 8).
- Observe a distance of at least 5 cm between the lower edge of the radiator and the bench (see fig. 7).
Horizontal installation:
- The distance from the floor must be at least 8 cm.
- The distance to the bench must be at least 10 cm (see fig. 7).
- The horizontal distance between radiator and all inflammable parts (e.g. wooden protection grille or back rest)
must be at least 4 cm (see fig. 7)
fig. 7

ELECTRICAL CONNECTION:

The radiator is factory equipped with a temperature resistant silicone connecting cable (SIHF 3G1.5) with plug
connector and may only be operated with a suitable control unit. The control unit must be placed outside the cabin.
Attention: Please observe all notes and warnings.
EN
12