Herunterladen Diese Seite drucken

AEG FRTD 903 TC Anleitung Seite 8

Vorschau ausblenden Andere Handbücher für FRTD 903 TC:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

FRTD 903 TC
FIG. 6 + 7 - MOUNTING THE THERMOSTAT
1. Mount the thermostat in the wall socket.
2. Fit the frame and carefully press the cover onto the thermostat
- starting with the upper part of the cover, then the lower part of
the cover. Ensure that both the power slide button on the cover
and the power switch pin in the thermostat are down.
3. Click the cover into place by applying light, even pressure.
Warning! Do not apply pressure to the corners of the display
cover or to the display itself.
DO NOT open the thermostat by releasing the four fixing clips on
the back.
FIG. 8 - OPERATING THE THERMOSTAT
There is an ON/OFF switch on the left side of the thermostat: up is
ON - down is OFF.
The resistive touchscreen requires a soft tap with your fingertip to
register the touch.
Installer Wizzard:
The first time the thermostat is connected, push the power slide
button to On "I" The Installer Wizard on the touchscreen will guide
you through the set up of:
1. Region
2. Language
3. Date
4. Time
5. Floor Type
Programming
See user manual.
http://www.aeg-haustechnik.de/fachpartner/produkte/gaw/fuss-
bodenheizungen/
14
© 2016 OJ Electronics A/S - EHT Haustechnik GMBH
English
FRTD 903 TC
FIG. 9 - TROUBLESHOOTING
If the sensor is disconnected or short-circuited, the heating system
is switched off. The sensor can be checked against the resistance
table.
Error codes
E0: Internal fault. The thermostat must be replaced.
E1: Built-in sensor defective or short-circuited. Replace the ther-
mostat, or use the floor sensor only.
E2: External sensor disconnected, defective or short-circuited.
Reconnect the sensor if disconnected, or replace the sensor.
E5: Internal overheating. Inspect the installation.
CE marking
According to the following standard:
LVD/EMC: EN 60730-1: 2011, EN 60730-2-9: 2010
Classification
Protection from electric shock must be assured by appropriate
installation. Appropriate installation must meet the requirements of
Class II (enhanced insulation).
Environment and recycling
Please help us to protect the environment by disposing of the
packaging in accordance with national regulations for waste
processing.
Recycling of obsolete appliances
Appliances with this label must not be disposed of with
general household waste. They must be collected
separately and disposed of in compliance with local
regulations.
© 2016 OJ Electronics A/S - EHT Haustechnik GMBH
English
15

Werbung

loading