6. Change runtime during operation
You can only change the runtime of the simalube during operation if you use the
"time" mode together with the simatec app.
1.
Change the runtime in the simatec app.
2.
Set the cartridge on the dispenser to the same runtime.
7. Replacing the lubricator
1.
The dispenser must be pressure free. To do this, carefully remove the cartridge.
2.
Unscrew the empty lubricator and either replace or refill it. When doing so,
follow the instructions in the simalube user manual.
3.
Remove the used battery pack and replace it with a new one.
4.
Check and clean the seal on the IMPULSE before inserting the new battery
pack. The IMPULSE remains at the lubrication point and can be reused
multiple times.
5.
For more information, see chapter "Installation and start-up" (p. 15, ch. 4, pt. 7).
6.
If the IMPULSE is registered in the app, the size and runtime must be updated.
8. Disposal
Used battery packs and simalube gas generators must be recycled in a battery
recycling system. Do not reuse, charge, open or throw batteries in a fire. The
IMPULSE device (without the battery pack) must be disposed of in accordance with
Directive 2012/19/ EU (WEEE).
Protect the environment by recycling valuable resources and observe your coun-
try's disposal directives.

9. Maintenance

The IMPULSE is maintenance-free. When replacing the lubricator, check the
housing and gasket and wipe them clean. If cracks appear in the housing of the
IMPULSE, the device must be disposed of.
For detailed information and control over the IMPULSE connect, it is possible to
connect the IMPULSE with the simatec app "simatec world of maintenance". The
unique Bluetooth
®
code is printed on the IMPULSE.