7 Climate rating
The
climate
rating
temperature at which the appliance may be
operated
to
achieve
performance. The climate rating is indicated on
the type plate.
Climate rating
Room temperature
SN
+10 °C to +32 °C
N
+16 °C to +32 °C
ST
+16 °C to +38 °C
T
+16 °C to +43 °C
SN-ST
+10 °C to +38 °C
SN-T
+10 °C to +43 °C
Do not operate the appliance outside the
specified room temperature range!
8 Appliance dimensions
9
indicates
the
room
full
refrigeration
Electrical connection
• Only
operate
the
alternating current (AC).
• The permissible voltage and frequency
are indicated on the type plate. The
position of the type plate is shown in the
section
entitled
appliance.
• The socket must be properly earthed and
protected by a fuse.
• The tripping current of the fuse must be
between 10 A and 16 A.
• Do
not
use
stand-alone
(conversion
of
alternating/three-phase
energy-saving plugs. Risk of damage to
the electronic control system!