Selection NET / GROSS:
N.SEt1
The threshold is compared with the net weight or with the gross weight.
Selection N.A. / N.C.:
The related output is normally open or normally closed.
Selection POSITIVE / NEGATIVE:
The threshold is compared only with positive weights or only with negative weights.
Selection NORMAL / STABLE:
The relative output is activated even when it is in motion or only after the weight has
stabilized.
Hysteresis of thresholds
IStEr1
For each of the 4 thresholds, a hysteresis value can be programmed that has the fol-
lowing function:
When the weight reaches a threshold, the respective output is enabled; this output
remains enabled until the weight differs, with respect to the threshold, from the pro-
grammed hysteresis value.
For example, with threshold 1 = 1000, hysteresis = 10, operating mode "nA" and
"norMAL ": the threshold 1 output is enabled at the value 1000 and is disabled at the
weight value 990
If the programmed value is 0 or if it is equal to or greater than the relative threshold,
the hysteresis control is excluded.
Default value: 2 divisions.
The same parameters are repeated for the four thresholds
Selection of the function of output 4
Fun2 4
SET: The output is related to the threshold 4
PROCES: The output 4 is activated when the weight is valid and a programming
phase is not in progress, e. g. when the weight threshold control is active. In this
case, the only valid selection is N.A. / N.C., while the threshold value of thresh-
old 4 has no meaning