10.2
WLAN data communication between controller and tool
Problem
No WLAN data communi-
cation between the
controller and tool.
IP address cannot be
pinged.
Occasional interruptions in
WLAN data communica-
tion.
Apex Tool Group
Possible cause
Remedy for mPro400GCD (SW S168813)
The IP address of the tool
1.
is not correctly entered in
the control.
2.
IP address of tool – see Tool in submenu Wireless Set-
tings.
Tool not yet parameter-
ized with the correct
WLAN settings.
WLAN settings are differ-
ent for tool and access
point.
A filter for MAC addresses
is activated at the Access
Point.
MAC adress of tool – see
Port 4001 is disabled by a
firewall.
The wireless channel at
the access point is outside
the range supported by
the tool.
Tool is already assigned to
another control.
IP Address already exists
in network. In this case,
the tool will not build up a
connection.
Distance between the
1.
access point and the tool
is too great.
2.
The tool is already
1.
assigned to another con-
trol.
2.
Excessive data traffic on
Reduce data traffic on WLAN Network.
WLAN Network.
1.
2.
P2390BA | 2019-03
On the control screen Tool Setup, check whether
the IP address of the tool has been entered in the
field Type.
Otherwise, mark the line and <Edit>.
Use LiveWire RF Configuration Software to setup
tool.
Reconfigure the tool (network name, encryption,
network key).
Add the MAC address for the tool to the list of
approved addresses at the Access Point.
Label above the battery
On the tool in the Wireless Settings submenu.
Configure the firewall such that the required IP/MAC
addresses can use port 4001.
Change the wireless channel setting at the access
point to the right wireless channel with respect to
country code. See Quick reference guide, CellCore
installation, P2402KA.
Check whether another control already has a con-
nection to this tool. In other words, another tool is
using the same IP address.
Check the physical connection (RSSI values).
Check the assigned IP address.
On the tool use WLAN icon to check signal strength
at the tool.
If necessary, reduce the distance between the
access point and the tool.
Check whether the tool (IP address) is also
assigned to another control.
If yes, delete the assignment in the other control.
A tool can only be assigned to one control.
On the control screen Basic, increase the Initial
Torque.
On the control screen disable the torque graph data
transmission:
Advanced > Controller > General > Trace Recording