8.3 Transmission fluid replacement

- Oil change after 200 hours of operation (30 days)
of a new machine. Afterwards, replace oil every 1000
hours (6 months). The mentioned horizon is based on
the assumption of an everyday 8-hour service.
- The oil indicator is next to the display. Put the feeder
to the displayed position (see pic.22) to see the oil
status.
- Rotate the feeder away from your workbench into
free space, open the cover, turn the feeder upside
down, release the oil cap and let some oil out. When
all the oil is gone, place the feeder to a vertical
position and pour in the transmission fluid according
to the oil indicator.
- Recommended gear oil: MOBIL Mobilgear 630,
Shell/Omala 150 BP, Energol GR-XP 150, and other
equivalents.
- Clean the machine after every use (dust, shavings
etc.).

9. MALFUNCTION ASSISTANCE

9.1 Error messages

E1 - Motor will not start: Check that there isn't
anything stuck in the feeder.
E2 - Drive mechanism temperature is too high.
E3 - Engine temperature is too high.
8
.21
pic
Obr. 25
Obr. 26
• After removing a probable malfunction - restart the
main switch.
• If you are not sure why a problem occurred, please
contact technical support.

10. PROTECTION OF THE ENVIRONMENT

Protect the environment.
Your machine contains materials that can be recycled.
Please, let specialized institutions handle the
machine.

11. ACCESSORIES (SPARE PARTS)

IGM Spare roller D120x60 for DC30-DC40 Feeders
IGM Narrow spare roller D120x25 for DC30-DC40
Feeders
IGM Swivel Cone Kit 0 - 90° set for Feeders DC30-DC40
141-R12060
141-R12025
141-KS