PC CONNECTION
Connect the USB Interface to the control panel before connecting it to the PC.
Insert the supplied USB cable into connector B (fig.3) and into a PC free USB port.
If the interface is recognised by the operating system (Windows 2000, XP, Vista, Windows 7, Windows 8),
the PC will add a COM port which will be assigned a number after the already existing port.
Otherwise, it will be necessary to load the FDTI Drivers, available on the "FastPro" CD.
Once the connection to the PC is established, you can use the "FastPro" configuration SW (from ver. 2.0 )
to execute the programming and reception operations related to the alarms from the Control panel.
During the communication between the Control panel and the PC, the PC LED (fig.3) remains on.
For further information on how to use "FastPro" refer to the "Programming Manual".
Note:
The 1067/003 interface is usually used during the maintenance to program the control panel parameters.
If the "1067/450" is also connected to the control panel; it is necessary to disconnect the Flat cable 10ways
from the IT RS232 connected to the "1067/450" before carrying out any operation with the USB interface.

TECHNICAL SPECIFICATIONS

The interface is directly powered by the control panel; therefore, the max. consumption should also be
considered when measuring the general input of the system.
Rated supply voltage (from control panel via flat cable) .................................................................. 13.8 Vdc
Min/max operating voltage .................................................................................................... 9 Vdc ÷ 15 Vdc
Rated input current at 12 Vdc:
Standby (USB Key and PC not connected) ........................................................................................... 5 mA
With USB Key in reading/writing mode ....................................................................................... 65 mA Max
PC connected for communication ....................................................................................................... 15 mA
Maximum current supplied to the USB Memory Key ......................................................................... 100 mA
Dimensions (W x H x D) ................................................................................................... 92 x 110 x 30 mm