Continuation „Operating modes / OP modes of the Start/Stop interface":
• ANGLE (angle measurement)
For angle measurement, the desired position or angle output value per rotation can be
specified by means of parameter "ROUND LOOP VALUE". This output value is generated
as soon as the distance covered (e.g. circumference), which is set as the reference value
in the parameter "CIRCUMFERENCE (in mm)", is reached. Afterwards the output value
starts again at 0 until the covered distance is reached again. (Round Loop Function!)
Using existing scaling parameters (Factor, Divider and Additive Value), this output value
can be rescaled if desired.
Interpretation of the measurement result during angle measurement:
The default setting ("CIRCUMFERENCE (mm) = 100.000" and "ROUND LOOP VALUE =
360", as well as "FACTOR = 1", "DIVIDER = 1" and "ADDITIVE VALUE = 0") corresponds to
an angle output or position output of "0...360" (e.g.: degrees) every 100.000 mm.
• SPEED (speed measurement)
The speed is recorded and can be converted again into another unit using existing scaling
parameters (Factor, Divider and Additive Value), if desired.
Interpretation of the measurement result during speed measurement:
The default setting ("FACTOR = 1", "DIVIDER = 1" and "ADDITIVE VALUE = 0") corresponds
to a velocity output in meters per second [m/s].
The parallel output and the linearization function always refer to the
scaled measuring result of the selected operational mode!
(Measurement_Result)