Continuation „Mode Start/Stop":
CIRCUMFERENCE (mm)
Setting the reference size (in "mm") for an angle measurement.
The distance covered (e.g. circumference) at which the subsequent output value (ROUND LOOP
VALUE) is to be generated must be set here.
(Note: Only for OPERATIONAL MODE: "ANGLE")
00000.001
01000.000
99999.999
ROUND LOOP VALUE
Setting of the desired measured value to be generated when the previous reference value
("CIRCUMFERENCE") is reached.
(Note: Only for OPERATIONAL MODE: "ANGLE")
1
360
99999999
AVERAGE FILTER – POSITION
The average value can be switched to avoid position fluctuations.
0
1
2
3
4
STANDSTILL TIME (s)
This parameter defines the time for standstill definition. If standstill is detected, standstill is
signalled after xx,xx seconds.
0,01
1,00
99,99
AVERAGE FILTER – SPEED
The average value can be switched to avoid velocity fluctuations.
www.balluff.com
Smallest value
Default value
Highest value
Smallest value
Default value
Highest value
(filter for average value)
No average value
Flowing mean value with 2 cycles
Flowing average value with 4 cycles
Flowing average value with 8 cycles
Flowing mean value with 16 cycles
Shortest delay time in seconds
Default
Longest delay time in seconds
(filter for average value)
No average value
0
Flowing mean value with 2 cycles
1
Flowing average value with 4 cycles
2
Flowing average value with 8 cycles
3
Flowing mean value with 16 cycles
4
19