Herunterladen Inhalt Inhalt Diese Seite drucken

H-tronic Automatiklader AL 600plus Handbuch Seite 14

Vorschau ausblenden Andere Handbücher für Automatiklader AL 600plus:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

AUTOMATIC CHARGER
AL 600plus
Art.- No.: 2 24 22 17
The Temperature Switch TSM 125 is well suited for all
The Automatic charger AL 600plus with diagnostic
operating ranges where a temperature control for heating
function operates with the most modern characteristic-controlled
charging technology and thus ensures ideal charging conditions
or cooling is required, e.g. central heating, air-conditioning
and maintenance of lead batteries. Intelligent software constantly
systems, refridgerator, incubator etc. The device can be used in-
monitors all functions and controls the correct charging proce-
dependently and it can also serve as a replacement for defective
dure. The battery can remain connected for months (e.g. during
mechanical thermostats and digital thermometers.
winter). Overcharging is not possible.
Features
– Multi-stage I/U charging characteristic I-phase, U1-phase, U2-phase
– Electronic protective circuit protects against reverse polarity and shortcircuit
– Automatic battery maintenance mode (Automatic refreshing of the battery
after charging)
– Software controlled diagnosis of the battery before beginning the charging
procedure, battery test function,
defect identification
– Trickle charging
– For 2 V, 6 V and 12 V lead
batteries (Acid, gel, AGM)
– Charging current max. 0.6 A
(automatic adaptation)
– 5 LED status displays: Mains,
charging, refresh, finished, error
14
Technical data
– Input voltage: 220 – 240 V/AC
– Max. charging current 600 mA
(12 V), 300 mA (2 V/6 V)
– Capacity of battery: 1,2 – 40 Ah
– Electronic protection against short-
circuits and incorrect polarity,
overcharging protection
AUTOMATIC CHARGER
GB

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

2 24 22 17

Inhaltsverzeichnis