Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaner Maintenance - Hoover H-FREE 300 HYDRO Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für H-FREE 300 HYDRO:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 23

CLEANER MAINTENANCE

Emptying the Dust Cup
1. Press the handheld release button and remove the tube. [1b]
2. Press the dust cup release button to release the bin flap and empty the contents. [11]
3. Close the dust cup flap, you will hear a click when fully locked.
NOTE: It is recommended to empty the dust cup after each use or when dust is up to the max fill lines.
Cleaning the Dust Cup and Filter
1. Press the handheld release button and remove the tube. [1b]
2. Press the dust cup release button to release the dust cup and empty the contents. [11]
3. Close the dust cup flap, you will hear a click when fully locked.
4. Press the battery pack release button and remove the battery pack. [2b]
5. Press the dust cup release button placed on the rear side of the dust cup and turn it anticlockwise pulling away from
the unit. [12]
6. Remove the Pre-Motor filter pulling the support from the dust cup. [13]
7. Remove the single cyclone system pulling the metal ring from the dust cup. [13]
8. Pull the single cyclone system and rotate the Single cyclone vortex finder in anticlockwise direction and then take it
out. [14]
9. Wash the filter and single cyclone system in lukewarm water and leave to dry for 24 hours. [15,16]
10. Reassemble once completely dry and refit to the product. [17,18,19,20]
NOTE: Do not use hot water or detergents when cleaning the pre-motor filter. In the unlikely event of the pre-motor filter
becoming damaged, fit a genuine Hoover replacement.
Do not use the product without pre-motor filter fitted before assembling dust cup to the main body.
IMPORTANT: For optimum performance, always keep your filter clean.
NOZZLE MAINTENANCE
Cleaning the 360° hydro roller, Hybrid Care roller, rear wiper blade and front wiper blade.
IMPORTANT: Always switch off the cleaner before cleaning the 360° Hydro roller and Hybrid Care roller, rear wiper blade
and front wiper blade.
Cleaning the 360° Hydro roller
1. Remove the nozzle from the tube. [22]
2. Detach the 360° Hydro roller release flap. It is positioned on the lateral side of the nozzle. [4a]
3. Remove the sealing cap and ensure the water tank is empty. [4b,4c]
4. Wash the 360° Hydro roller and the sealing cap in lukewarm water with a gentle detergent by squeezing it or wash it in
washing machine using gentle cycle without the 360° Hydro roller release flap. [4d]
5. Leave it to dry in upright position for at least 24 hours. [4e]
6. Re-fit 360° Hydro roller on the nozzle to its starting position.
7. Close the 360° Hydro roller release flap to the nozzle.
IMPORTANT: It is recommended to wash the 360° Hydro roller after every cleaning and to leave to dry in upright position
for at least 24 hours.
IMPORTANT: Do not leave the wet 360° Hydro roller in the nozzle.
IMPORTANT: The vacuum function on carpets should only be used when the Hydro Roller is completely dry.
NOTE: If you prefer to wash it in the washing machine, it is recommended to use a gentle cycle below 40°and to remove
the 360° Hydro roller release flap. [4d]
Cleaning the Hybrid Care roller
1. Remove the nozzle from the tube. [22]
2. Detach the Hybrid Care roller release flap. It is positioned on the lateral side of the nozzle. [23]
3. Hold the Hybrid Care roller release flap and remove it from the nozzle.
4. To clean the Hybrid Care roller, remove excess debris using scissors. [23]
5. Re-fit the Hybrid Care roller. It can be fitted only in one direction. [23]
6. Close the Hybrid Care roller release flap to the nozzle.
Cleaning the rear wiper blade:
1. Remove the nozzle from the tube. [22]
2. Push the end side release flap and remove the rear wiper blade. [24]
* Certain Models Only
6
GB

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis