Sweep and Maintain
Before sweeping and maintaining, please cut off the power supply in order to prevent the accident.
-
After daily work, please take out the plates to clean, and use the soft towel which has no corrosive
-
cleanser to clean its surface. Forbid to use the water to wash it directly in order to prevent to damage
its electricity function.
Please don't use the furnace to bake the food which has too much sugar and over-heated flows, in
-
order to prevent pollution of the stoves, and effect the furnace performance.
Electricity Principle Diagram
N
L
E
HL1...电源指示灯 ∞...电风扇 EH1、EH2...电
HL1- power indicator
热管 R...调速 M...电动机 QS...挡位开关
R—adjust speed

General Troubleshooting

Phenomenon
Connect the power supply, the
indicating light is not bright,
the knob is not rotating, and
the heating pipe doesn't work.
The power indicating light is
bright, but the rotating axis
doesn't work.
The power supply indicating
light is bright, but the heating
pipe doesn't work.
QS
2
P1
EH1(下)
3
P2
EH2(上)
4
HL
R
M
EH1—down heating pipe
M—motor
QS—stalls switch
reasons
1.The Master switch is off.
1.Some of the motor line is
Loosen or shedding.
2.The motor is burned out.
1.Some of the heating pipe
line is Loosen or shedding.
2. The heating pipe is
burned out.
D
o
w
Stalls map
90°/stall
挡位图(每挡位旋转90°)
n
P2
P1
P3
此挡位没用
pn
EH2—upper heating pipe
Handling Methods
1.Check the line whether
there exists electricity
leakage, turn off the master
switch.
1.Check and tighten the
connection of the motor
line.
2.Change the motor.
1. Check and tighten the
connection of the lighting
line.
2. Change the heating pipe.