You can adjust the HLC 2 EM to different source power outputs of OEM stereo or OEM amplifier thanks to
HPI-circuit. Position 20 W is suitable for most OEM stereos and most of OEM amplifiers. However, some special
OEM-amplifiers deliver more than 20 W RMS output. You have to switch to 60 W position in this case.
Attention: If you are not sure about output power of you OEM system ask a dealer or specialist, please.
The HLC 2 EM has an automatic signal detection circuit (SE-technology). It is automatically used if
OEM stereo doesn't use BTL amplifier topology.
If using signal detection to turn on,HLC 2 EM will switch off remote by a pre-defined time delay. This is
neccessary to avoid switching off in low volume passages in music or speach.
The HLC 2 EM uses an advanced speaker load simulation technology called PRS-technology. It is
always present and is for avoiding fault code messages and switch off situations of speakers by OEM stereo
due to error checking techniques of OEM-amplifier.
Power Supply Voltage
Signal to Noise Ratio
Frequency Response
Channel Separation
Fuse to use
Maximum Input Voltage
Dimensions
ADJUSTING TO INPUT POWER (HPI)
Position 20 W:
OEM-stereo and OEM-amplifier with up to 20 W maximum
RMS power output.
Position 60W:
OEM-amplifier with up to 60 W maximum RMS power
output.
signal detection (SE)
SWITCH-OFF Dela y (SE)
adv anced speaker load simulation
technical dat a
60 W RMS
43(W) x 13(H) x 35(L) mm