D
F
Betriebs- und Montagean-
leitung
Gas- und Luftdruckwächter
GW...
GW.../2
FIN
LGW.../3
LGW ... /3U
Luftdruckwächter
LGW ... /2
Doppeldruckwächter
GW ... / GW ...
[mbar]
EN 1854
EN 161
100 – 500 mbar
30 – 150 mbar
2,5 – 50 mbar
1 – 10 mbar
0,4 –
3 mbar
[ V ]
Ag
[A]
EN 1854
1 ... 8
GB
F
NL
E
Operation and assembly
instructions
Gas and air pressure switch
GW...
GW.../2
DK
S
LGW.../3
LGW ... /3U
Air pressure switch
LGW ... /2
Double pressure switch
GW ... / GW ...
Max. Betriebsdruck / Max. operating
pressure/ Pression de service maxi. Max.
pressione di esercizio
siehe Tabelle Seite 2
Refer to table on page 2
Voir tableau page 2
vedere tabella alla pagina 2
Druckwächter/Pressure Switch
Pressostat/ Pressostato
Typ/Type/Type/Tipo
GW ...
LGW ...
nach / acc. / selon / a norme
DIN 3398, EN 1854
Einstellbereiche /Setting ranges
Plages de réglage/
Campi di taratura
siehe Tabelle Seite 2
Refer to table on page 2
Voir tableau page 2
vedere tabella alla pagina 2
~(AC) eff., min./mini 10 V,
~(AC) max. /maxi. 250 V
=(DC) min./mini. 12 V,
=(DC) max. /maxi. 48 V
Nennstrom/nominal current/courant
nominal/corrente nominale
~(AC) 10 A
Schaltstrom/current on contact/cou-
rant de commutation/corrente di
intervento
~(AC) eff., min./mini 20 mA,
~(AC) max./maxi. 5 A cos ϕ = 1
~(AC) max./maxi. 3 A cos ϕ = 0,6
=(DC) min./mini. 20 mA
=(DC) max./maxi. 1 A
I
P
Notice d'emploi et de
montage
Pressostat pour gaz et air
GW...
GW.../2
N
LGW.../3
LGW ... /3U
Pressostat pour air
LGW ... /2
Pressostat double
GW ... / GW ...
¡C
+60
0
-15
¡C
+60
0
-15
¡C
+80
0
-30
Gas Gaz
IEC 529
IEC 529
Istruzioni di esercizio e di
montaggio
Pressostato per gas e aria
GW...
GW.../2
LGW.../3
LGW ... /3U
Pressostato per aria
LGW ... /2
Pressostato doppio
GW ... / GW ...
Umgebungstemperatur
Ambient temperature
Température ambiante
Temperatura ambiente
–15 °C ... +60 °C
Mediumstemperatur
Medium temperature
Température du fluide
Temperatura fluido
–15 °C ... +60 °C
Lagertemperatur
Storage temperature
Température de stockage
Temperatura stoccaggio
–15 °C ... +80 °C
LGW .../2
Luft- und Rauchgase
Air and flue gases
Air gaz et fumées
Aria e gas di combustione
GW..., GW ... / GW ...
GW.../2
LGW.../3, LGW ... /3U
Familie / Family/ Famille / Famiglia
1 + 2 + 3
Schutzart / Degree of protection
Protection / Protezione
nach / acc. / selon / a norme
IEC 529 (EN 60529)
siehe Tabelle Seite 2
Refer to table on page 2
Voir tableau page 2
vedere tabella alla pagina 2