7

USE

To use the fan coil refer to the instructions on the control panel
available as accessory.
ATTENZIONE: For safety reason, do not introduce your fin-
gers or other pointed objects in the air outlet grilles.
DANGER:
The unit may be used by children of at least 8
years of age and by persons with reduced physical, sensory,
8

MAINTENANCE

For safety reasons, before carrying out any maintenance or
cleaning jobs, turn off the unit by moving the fan speed se-
lector to "Off" and putting off the main switch (0 position).
DANGER!
Due caution must be taken while carrying out
maintenance: some metal parts may cause injuries; wear
protective gloves.
The maintenance requirements of FWP ducted units are limit-
ed to periodic cleaning of the air filter and heat exchanger and

CLEANING THE AIR FILTER

Disconnect the unit from the power supply by setting the main
switch on 0 (OFF).
To clean the air filter proceed as follows:
1. Access the unit via the inspection panel and take out the air
filter as shown in p-63 Cleaning the air filter ):
2. If the filter is on the inside of the intake grille, remove the

CLEANING THE HEAT EXCHANGER

It It is advisable to check the condition of the exchanger before
the start of every summer season to make sure that the fins are
not obstructed by dirt.
To access the heat exchanger, remove the outlet panel (whether
of the type with collars or a rectangular flange) and the drip tray.
On reaching the exchanger, clean it with compressed air or
low-pressure steam taking care not to damage the fins.
Before the start of every summer season, check the efficiency of
condensate drainage.
Adequate periodic maintenance will ensure save both ener-
gy and cost savings.
8
FWP
or mental capabilities, or who lack experience or the neces-
sary knowledge, provided that they are supervised or after
they have received instructions relating to the safe use of the
unit and understand the inherent dangers. Children must
not play with the unit. Cleaning and maintenance to be car-
ried out by the user must not be performed by unsupervised
children.
checks on the efficiency of condensate drainage.
Maintenance may be performed only by specialised
personnel.
Whenever starting up the unit after it has not been used for a
long time, check that there is no air in the heat exchanger.
The motor requires no maintenance since it has self-lubricating
bearings.
latter and then proceed to carry out the steps described
below.
3. Clean the filter with warm water or, in the event of dry dust
build-up, using compressed air.
4. Allow the filter to dry and then fit it back in place.
Air filter dimensions, see figure p.62.