13.7 Mounting of direct air connection on the TT60W

1.0. New TermaTech wood-burning stove

Congratulations on your wood-burning stove.
We thank you for choosing a TermaTech wood-burning stove and hope that you will have many
cosy and warm moments in the future.
Before using the stove you should read the user and mounting manual so that you are familiar
with the legal requirements as well as the instructions regarding maintenance. By this it is ensu-
red that the product functions as intended and you get the most out of your investment for many
years to come.

2.0. Installation instruction

INSTALLATION INSTRUCTIONS IN SMOKE CONTROL AREAS
Installation in a smoke control area requires the additional assembling / installation of the "Dam-
per control unit" which must be installed by the installer. See drawing and picture on page 47.
The stove is intended for "intermittent combustion" it is not meant to "heat over" night. By fol-
lowing the instruction below in "lighting instruction" the best and most environmentally friendly
combustion is achieved.
The wood-burning stove is delivered ready for Installation (ensure the correct outlet socket is
used, sealed and secured) and must be connected to the chimney with a smoke (flue) pipe. The
connection between stove and chimney must, as far as possible, be mounted in one straight piece
(with as few bends as possible) any horizontal section must be kept to a maximum of 150mm,
but preferably rising vertically from the stove to the chimney (all Joints must be tight) with an ac-
cess for sweeping smoke (flue) pipe.
EN15287-1 allows an 'Acceptable Alternative method' e.g. 450mm horizontal section of connec-
ting smoke (flue) pipe into a chimney system, please ask your supplier for details.

2.1. Placement of the stove

Distance to walls and flammable material. See section 12.1 & 12.2 & 12.3.
TT60W must be wall mounted at least 320mm above the floor.
2.2. Floor requirements
The floor underneath must be able to support the combined weight of the stove and possibly the
chimney.
The stove must be mounted on a non flammable surface. The surface should at least cover
150mm to each side of the oven and 300mm in front of the stove opening.

2.3. If the stove is to be mounted with a rear outlet, then do the following

Remove (possibly break off) the cover plate at the rear of the stove, all the way to the burning
chamber which provides free passage to the chimney. Subsequently remove the cover plate which
is screwed on the burning chamber. The universal nozzle which is mounted on the top of the stove
is removed and mounted on the rear of the stove. The cover plate which was mounted at the rear
of the stove is now at the top of the stove. The chimney is now ready to be installed.
TT60W is mounted with rear outlet from the factory

2.4. Requirements for the chimney

The chimney must be of sufficient height so that the draught conditions are good and so that the
smoke does not bother any neighbours. Good draught in the chimney is crucial to the stove work-
ing as intended and burns as environmentally friendly as possible. All joints and connections must
be tight and the chimney must be able to provide a draft of at least 1,2mm water gauge (12Pa)