Herunterladen Inhalt Inhalt Diese Seite drucken

New Termatech Wood-Burning Stove; Installation Instruction; If The Stove Is To Be Mounted With A Rear Outlet, Then Do The Following; Requirements For The Chimney - TermaTech TT60 Serie Montage- Und Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für TT60 Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16

1.0. New TermaTech wood-burning stove

13.7 Mounting of direct air connection on the TT60W
Congratulations on your wood-burning stove.

2.0. Installation instruction

We thank you for choosing a TermaTech wood-burning stove and hope that you will have many
cosy and warm moments in the future.
Before using the stove you should read the user and mounting manual so that you are familiar
with the legal requirements as well as the instructions regarding maintenance. By this it is ensu-
red that the product functions as intended and you get the most out of your investment for many
years to come.
INSTALLATION INSTRUCTIONS IN SMOKE CONTROL AREAS
Installation in a smoke control area requires the additional assembling / installation of the "Dam-
per control unit" which must be installed by the installer. See drawing and picture on page 47.
The stove is intended for "intermittent combustion" it is not meant to "heat over" night. By fol-
lowing the instruction below in "lighting instruction" the best and most environmentally friendly
combustion is achieved.
The wood-burning stove is delivered ready for Installation (ensure the correct outlet socket is
connection between stove and chimney must, as far as possible, be mounted in one straight piece
(with as few bends as possible) any horizontal section must be kept to a maximum of 150mm,
but preferably rising vertically from the stove to the chimney (all Joints must be tight) with an ac-
12.1 Safety distance to inflammable
12.3 Safety distance to inflammable TT60W
EN15287-1 allows an 'Acceptable Alternative method' e.g. 450mm horizontal section of connec-

2.1. Placement of the stove

2.2. Floor requirements
chimney.
150mm to each side of the oven and 300mm in front of the stove opening.

2.3. If the stove is to be mounted with a rear outlet, then do the following

chamber which provides free passage to the chimney. Subsequently remove the cover plate which
is screwed on the burning chamber. The universal nozzle which is mounted on the top of the stove
is removed and mounted on the rear of the stove. The cover plate which was mounted at the rear
of the stove is now at the top of the stove. The chimney is now ready to be installed.
TT60W is mounted with rear outlet from the factory

2.4. Requirements for the chimney

smoke does not bother any neighbours. Good draught in the chimney is crucial to the stove work-
ing as intended and burns as environmentally friendly as possible. All joints and connections must
be tight and the chimney must be able to provide a draft of at least 1,2mm water gauge (12Pa)
used, sealed and secured) and must be connected to the chimney with a smoke (flue) pipe. The
cess for sweeping smoke (flue) pipe.
ting smoke (flue) pipe into a chimney system, please ask your supplier for details.
Distance to walls and flammable material. See section 12.1 & 12.2 & 12.3.
TT60W must be wall mounted at least 320mm above the floor.
The floor underneath must be able to support the combined weight of the stove and possibly the
The stove must be mounted on a non flammable surface. The surface should at least cover
Remove (possibly break off) the cover plate at the rear of the stove, all the way to the burning
The chimney must be of sufficient height so that the draught conditions are good and so that the
39
39
40
40
40
40
40
40
41
41
41
42
43
47
31

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Tt60s serieTt60w serie

Inhaltsverzeichnis