Herunterladen Inhalt Inhalt Diese Seite drucken

Setting Change When Moving From Lighting To General Operation; Relighting When The Stove Is In Operation - TermaTech TT60 Serie Montage- Und Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für TT60 Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16
If the wood has the right water content it will start to burn after approx. 20 to 45 seconds.
To make sure that no soot and tar is formed in the chimney, only use wood with a water
content between 15 and 20%. The water content can be measured with a moisture meter.
3.7.5. The setting change when moving from lighting to general operation
Close the door when yellow/light flames appear. The start-up air must be closed (the knob
on the left under the door). The stove is now controlled by the secondary air (right knob
under the door).
If a slower combustion is wanted then push the secondary knob further in, depending on the
level desired. However never close it completely.
To ensure good combustion and a good airflow in the chimney it is a good idea to keep an
eye on the chimneys temperature if possible. This can be measured on a non isolated chim-
ney about 1 m above the stove with a TermaTech chimney thermometer. A good temperature
for the chimney is between 100 and 300 degrees c°.

3.7.6. Relighting when the stove is in operation

When the wood has burnt to embers carefully open the door and add 2-3 pieces of wood
(1,5-2kg.)
Close the door and control the stove with the secondary air (knob on right). If extra air is
needed open the start-up air (knob to the left) for a period of max 10 minutes.
Incidents
The glass door soots up
Solution
The fire in the burning chamber is not hot enough. Open for the secondary air and the soot
will burn off quickly.
The wood is too moist.
A lack of draught in the chimney.
34
TermaTech moisture meter item number: 92-150
TermaTech chimney thermometer item number: 92-162

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Tt60Tt60sTt60wS01-670S01-672S01-674

Inhaltsverzeichnis