ELECTRIC HEATING CABLE
CTAV-10, CTAV-18
Twin conductor heating cables CTAV-10/18 are designed for installation in concrete or
into layer of glue and used both for new heating floors and renovated floors, also for frost
protection of outer staircases. Heating cables are laid directly on the concrete or old tiles in the
bathroom, kitchen, room or other premises.
Different flooring requires different heating cables. We recommend:
Recommended heating cable
CTAV-18 (100-150 W/m²)
CTAV-18 (100-120 W/m²)
CTAV-10 (100 W/m²)
CTAV-18 (250-300 W/m²)
1. TECHNICAL DATA
Conductor insulation thickness Fluorpolymere (FEP) - 0,3 mm
Over-jacket of heating cable PVC, thickness 0,8 mm,
Heating cable CTАV thickness 4,6 mm
Min. bending radius of heating cable Not less than 8 diameters of cable
Maximum temperature + 70
ATTENTION!
1.
Every heating cable should be used according the producer's recommendation.
2.
It should be correctly connected to the thermostat.
3.
The installation of heating system should be done only by approved specialist.
4.
The protection screen must be connected to the green-yellow earth wire.
2. CONCRETE FLOOR HEATING
The system of heating cables can be the main (the only) heating source of premises but
Indoor
Tiles on concrete: kitchen, room, hall
Tiles on concrete - F-BOARD floor insulation
Wooden floors: laminate, parquet, timber boards.
Outdoor
Heating of external stairs and staircases
Voltage 230V AC; 50-60Hz
Max. power 10 W/m; 18 W/m
Protection screen 14 tinned copper wires with diameter of
1 mm
Protection class IP 67
Applied standards Compatible with IEC 60800
Floor surface
+ 0,3 mm aluminium foil (AIPEL)