Herunterladen Inhalt Inhalt Diese Seite drucken

Battery Controller BC X-PRO 60 Benutzerhandbuch Seite 16

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 37
AGM/EFB: perfect charging algorithm for batteries installed on vehicles equipped with Start & Stop
systems, which require a different charging curve with higher voltages.
Ca/Ca: select this type to recharge calcium-calcium or lead-calcium batteries.
Litio: specific charging algorithm for the new generation of lithium-ion or lithium-iron-phosphate
starting batteries. It is possible to execute a partial charge for lithium batteries by selecting the
charging percentage to be reached: 25%, 50%, 75%, 100%. In fact, it is advisable to keep lithium
batteries in stock / on shelf at a charging percentage around 25/50% (see manufacturer's
instructions), to increase their life span
menus. After the initialization is complete, the first row of the LCD display always shows the chosen
parameters. The second row shows: "Load not connected!".
CHARGING MODE & PARAMETERS SELECTION
Before connecting the device to the battery, select the
"CHARGER" operating mode and set the charging
parameters as follows:
1. Press and hold the "ON/OFF - SELECT" button for 5
seconds to access the menu.
2. Press the arrow keys until you reach Menu: MODE.
Press "ON/OFF - SELECT" to confirm.
3. Select the operating mode CHARGER with the
arrow keys. Press the "ON/OFF - SELECT" button to
confirm the choice.
4. Select the battery type with the arrow keys:
STD/MF – Lithium – AGM/EFB – Ca/Ca. Press the
"ON/OFF - SELECT" button to confirm the choice.
5. Select the maximum charging current with the
arrow keys. Note: select a maximum charging
current equal to a tenth of the battery capacity, or
to the value immediately higher in the scale of
selectable values (ex: for a battery with a capacity
of 80 Ah, maximum current 10.0 A). When
charging lithium batteries, it is possible to select a
higher maximum charging current, but a slow
charge is recommended anyway. Comply with the
battery manufacturer's instructions and instructions
for the maximum recommended charging current.
Press the "ON/OFF - SELECT" button to confirm the
choice.
6. Only for Lithium batteries: select the charging
percentage to be reached (25%, 50%, 75%, 100%).
Press the "ON/OFF - SELECT" button to confirm the
choice.
7. For all other batteries: select Desulph. ON/OFF to
enable or disable the desulphation cycle. It is
recommended to set this parameter as ON for used
batteries, OFF for new batteries. Press the "ON/OFF
- SELECT" button to confirm the choice.
The display shows "OK". BC X-PRO 60 restarts and
shows all parameters set in the "Mode" and "Safety"