Leak Testing Valves, Hoses and Regulator
1. Turn all control knob(s) to OFF
2. Be sure regulator is tighly connected to gas tank.
3. Completely open tank valve by turning manual valve. If you hear a rushing sound,
turn gas off immediately. There is a major leak at the connection. Correct before proceeding.
4. Brush soapy solution onto indicated connections showen below.
5. If growing bubbles appear, there is a leak. Turn off the gas supply in event of gas leak.
If leaks cannot be stopped, do not try to repair. Replace a new one.
6. Always close tank valve after performing tank leak test by turning manual valve.
7. Before each use, check to see if hoses are cut or worn. Replace damaged hose assembly
before using appliance. Use only valve/hose/regulator specified by manufacturer or seller.
WARNING
• Do not use appliance until leak checked.
• If you cannot stop a gas leak, immediately close gas tank valve and call gas supplier or your
fire department.
Lighting stove instruction
Do not lean over the oven while lighting.
1. Remove all appliances from the burner to create a free flow or air.
2. Open lid. Do not attempt to light the stove with lid closed.
3. Fully open LP bottle valve is using a bulk tank
4. Turn control valve slowly to the High position. Cooker will ignite. Adjust controls to desired
temperature.
5. If ignition does not occur in 5 seconds, turn the burner control(s) off, wait 5 minutes, and
repeat lighting procedure. If built-in ignitor will not light follow instructions for lighting with a
match.