5 | Control and display elements
5.2
Operating elements and
display indicators
The operating elements and display indicators are loc-
ated at the top left of the goods area.
Fig. 4: Operating elements
Keys are available as control elements, with the fol-
lowing assignments:
Key
Acknowledge acoustic alarm
Optional
Key
Switch the cooling function on
Activate temporary daytime op-
Start semi-automatic defrosting
Fig. 5: Display screens
Display
Unit defect-free and operational
Cooling function off (Standby)
42 / 220
Function
Function
and off
eration
(appliance lighting on)
Navigate to program level
Increase value
Navigate to program level
Reduce value
Meaning of display
Interior temperature
(Normal operation)
Cooling function active
Defrosting active
Cooling function active
Defrosting active
Evaporator ventilator active
Display
Day mode (appliance lighting
5.2.1

Cooling function

Switch off the cooling function for cleaning purposes
only.
Press and hold
seconds.
play.
Switch off cooling
Press and hold
function (Standby)
until
play.
Press
display.
Press and hold
seconds.
Switch on the cool-
temperature and the symbols
ing function
after a few seconds.
5.2.2

Semi-automatic defrosting

Press and hold
seconds.
play.
Press and hold
Start semi-automatic
until
defrosting
play.
Press
bols
play after a few seconds.
After semi-automatic defrosting, the appliance auto-
matically returns to normal operation.
5.2.3
Activate temporary daytime
operation - for loading
To switch on the appliance lighting during night opera-
tion.
Activate temporary day-
time operation
After 60 minutes, the appliance lighting switches off
automatically.
End temporary day opera-
tion early
5.2.4

Alarm

Display alarm
The error code appears on the display.
AHT Cooling Systems GmbH | en
Meaning of display
on)
Alarm
for 5
appears on the dis-
or
appears on the dis-
.
appears on the
for 5
or the internal
appear on the display
for 5
appears on the dis-
or
appears on the dis-
.
and both sym-
appear on the dis-
Press and hold
for 2
seconds.
appears on
the display.
Press and hold
for 2
seconds.
428175_1_0121