6. Troubleshooting and solutions:

Below are some of the most common causes that may lead to the described malfunctions.
If a system malfunction occurs, power supply MUST be cut off before attempting to run any diagnostics.
Alarm signals are as follows:
D
ETECTED SITUATION
Red triangle
Red triangle and
machine in lock mode
Red triangle and machine
in lock mode
Red triangle and machine
in lock mode
Red triangle and machine
in lock mode
Red triangle and machine
in lock mode
Red triangle
Red triangle
Red triangle
Red triangle
Red triangle
Red triangle
R
ED TRIANGLE
36
-Dati tecnici e caratteristiche soggetti a cambiamenti senza preavviso
-All specifi cation subject to change without notice
All manuals and user guides at all-guides.com
E
RROR DISPLAYED ON
D
ISPLAY
Maintenance alarm
Maximum time elapsed
without maintenance/clean-
ing
High condensation alarm
High
room temperature
High condensation alarm
Condenser clogged / dirty
High condensation alarm
Condenser probe
High condensation alarm
Condenser fan is not work-
ing
High condensation alarm
High inlet pressure
Low evaporation alarm
Ice on evaporator
Low evaporation alarm
Evaporator fan is not work-
ing
Low evaporation alarm
Evaporator probe dam-
aged/broken
Defrost time-out alarm
Ice on evaporator
Defrost time-out alarm
Evaporator fan is not work-
ing
Defrost time-out alarm
Evaporator probe dam-
aged/broken
Door 1 open alarm
Close the door
Alarm signal: this icon is displayed when there is an alarm on
the machine. To silence the sound alarm, press the icon
Display of alarms in progress.
For information, press the alarm string
Display of information useful to solve an alarm
C
: A
AUTION
LARMS IN PROGRESS WILL BE ELIMINATED ONLY IF THE
MACHINE IS RESTORED TO PROPER OPERATION
P
OSSIBLE REASON
Call a qualifi ed engineer
and inform him of the alarm
and product serial number
Ventilate the room
Do not obstruct the air in-
takes of the condenser and/
or clean it
Call a qualifi ed engineer
and inform him of the alarm
and product serial number
Call a qualifi ed engineer
and inform him of the alarm
and product serial number
Call a qualifi ed engineer
and inform him of the alarm
and product serial number
Run a defrost
Call a qualifi ed engineer
and inform him of the alarm
and product serial number
Call a qualifi ed engineer
and inform him of the alarm
and product serial number
Run a defrost
Call a qualifi ed engineer
and inform him of the read
error and product serial
number
Call a qualifi ed engineer
and inform him of the read
error and product serial
number
Call a qualifi ed engineer
and inform him of the read
error and product serial
number
-Technische Daten und Eigenschaften mit Änderungen ohne Anzeige
- Données techniques et caracteristiques suiettes à des changements sans avis
.
S
OLUTION
T
ECHNICAL SOLUTION
U
SER
Clean the condenser, check
fan operation, gasket seal,
then reset the machine
Replace probe S3
Replace fan
Check gas load and cooling
circuit
Replace fan
Replace probe S2
Replace fan
Replace probe S2
Check: input D1, door sen-