You will then gain access to the SERVICE functions.
Press "SCANNER"
This function is used to check that the components are enabled and properly connected.
To run the test on the single components, press "PLAY" and wait for the related "Ux" value to change to a red color, which
indicates "ON" status, and for the consumption in W for the tested component to appear.
Then, press the "PLAY" key again to move to the next component test.
After you have tested all the outputs, press the "HOME" icon.
The output acronym/component pairing are:
U1
Compressor
U2
Heating (optional)
U3
Door frame heater
U4
Pump-Down
U5
Sterilizer (optional)
-Dati tecnici e caratteristiche soggetti a cambiamenti senza preavviso
-All specifi cation subject to change without notice
All manuals and user guides at all-guides.com
U6
U7
U8
EV
Heated probe (optional)
Hot Gas
Internal lighting (optional)
Evaporator fans