Herunterladen Inhalt Inhalt Diese Seite drucken

Eufab 21076 Bedienungsanleitung Seite 9

Dual power kompressor mit 12 v und 230 v anschluss
Vorschau ausblenden Andere Handbücher für 21076:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
6.2.3 CONVERSION TABLE PSI / BAR
The units are converted as follows:
1 psi = 0.069 bar
psi
bar
10
0,7
20
1,4
30
2,1
40
2,8
50
3,4
60
4,1
Table 1
bar
psi
0,5
7
1,0
15
1,5
22
2,0
29
2,5
36
3,0
44
Table 2
6.3 REPLACING THE FUSES
6.3.1 REPLACING THE FUSE FOR THE 12 V SYSTEM
Rotate the tip (Position 17 in Figure 9) of the 12 V plug
(Position 15 in Figure 9) anti-clockwise until it comes away
from the plug and then remove. The fuse (Position 16 in
Figure 9) is exposed and can be removed from the plug.
Replace the fuse with another of the same strength and screw
the tip back into the plug, Figure 9.
Figure 9: Fuse in 12 V plug
6.3.2 REPLACING THE FUSE FOR THE 230 V SYSTEM
Open the storage compartment lid on the rear of the device.
Remove the connection cable and the air hose. See also Figu-
re 3 in the overview. Rotate the end cap (Position 18 in Figure
10) and remove. Remove the fuse (Position 19 in Figure 10)
from the holder (Position 20 in Figure 10). Replace it with a
new fuse of the same strength. Rotate the end cap back into
the holder.
Figure 10: 230 V fuse in storage compartment
1 bar = 14.504 psi
psi
bar
70
4,8
80
5,5
90
6,2
100
6,9
110
7,6
120
8,3
bar
psi
3,5
51
4,0
58
4,5
65
5,0
73
5,5
80
6,0
87
6.4 TROUBLESHOOTING
ERROR
The compressor is not functioning
The connection cable is not
POSSIBLE CAUSE
connected correctly.
Check the cable connection and
connect correctly.
MEASURE
When operating using a vehicle:
POSSIBLE CAUSE
No voltage to the on-board socket.
Switch on the ignition of your
vehicle. Check the fuse for the
MEASURE
on-board socket and replace
if necessary.
The fuses in the compressor have
POSSIBLE CAUSE
been triggered.
Replace the faulty fuse, see section
MEASURE
6.3
7. MAINTENANCE AND CARE
7.1 MAINTENANCE
When used according to the instructions, the Dual Power
Compressor is maintenance-free. Store the compressor in a
dry, frost-free location.
7.2 CARE
Switch the compressor off before cleaning, separate from the
power supply. Clean the housing of the compressor with a
soft, dry cloth. Do not use any aggressive cleaning agents or
solvent-based cleaners. Never allow liquids to penetrate the
housing.
8. NOTES REGARDING ENVIRONMENTAL PROTECTION
Do not dispose of electrical devices with house-
hold waste. Electrical devices and electronic
scrap must be collected separately and disposed
of in an environmentally responsible manner
for recycling. Please contact your community or
city administration regarding disposal options
for electrical and electronic scrap. The materials
are recyclable. You make an important contribu-
tion to protecting our environment by recycling,
material utilisation or other forms of reusing
waste equipment.
9. CONTACT INFORMATION
EAL GmbH
Otto-Hausmann-Ring 107
42115 Wuppertal, Germany
+49 (0)202 42 92 83 0
+49 (0) 202 42 92 83 – 160
info@eal-vertrieb.com
www.eal-vertrieb.com
9

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis