Herunterladen Inhalt Inhalt Diese Seite drucken

Xylem EBI 12 EX Serie Bedienungsanleitung Seite 55

Inhaltsverzeichnis

Werbung

English
EBI 12-T67x / EBI 12-T69x
Product line:
Design:
Measurement range:
Accuracy:
±0.2 °C (-20 °C ... 0 °C)
±0.1 °C (0 °C ... +120 °C)
±0.05 °C (+120 °C ... +140 °C)
±0.1 °C (+140 °C ... +150 °C)
Precision Pressure Logger
EBI 12-TP 19x / EBI TP 29x
Product line:
Design:
Measurement range: 0 °C ... +150 °C
0.1 ... 1,050 mbar
Accuracy:
±0.1 °C (0 °C ... +120 °C)
±0.05 °C (+120 °C ... +140 °C)
±0.1 °C (+140 °C ... +150 °C)
±0.25 mbar (0,1 mbar ... 50 mbar)
±5% v. MV (50 mbar ... 100 mbar)
±1 % FS (remaining range)
Pressure Logger
EBI 12-TP 22x / EBI TP 23x
Product line:
Design:
Measurement range: 0 °C ... +150 °C
1 ... 4,000 mbar
Accuracy:
±0.1 °C (0 °C ... +120 °C)
±0.05 °C (+120 °C ... +140 °C)
±0.1 °C (+140 °C ... +150 °C)
±10 mbar (50 mbar ... 150 mbar)
±10 mbar (2,050 mbar ... 2,250 mbar)
±10 mbar (3,000 mbar ... 3,250 mbar)
±20mbar (3,500 mbar ... 4,000 mbar)
±15 mbar (restlicher Bereich)
EBI 12-TP 32x
Product line:
Design:
Measurement range: 0 °C ... +150 °C
1 ... 4,000 mbar
Accuracy:
±0.1 °C (0 °C ... +120 °C)
±0.05 °C (+120 °C ... +140 °C)
±0.1 °C (+140 °C ... +150 °C)
±10 mbar (50 mbar ... 150 mbar)
±10 mbar (2,050 mbar ... 2,250 mbar)
±10 mbar (3,000 mbar ... 3,250 mbar)
±20mbar (3,500 mbar ... 4,000 mbar)
±15 mbar (restlicher Bereich)
2/2021 BA80122def05_EBI 12 Serie-EX
Redline
4 channel, flexible
cable probes
1.2 mm diameter
-20 °C ... +150 °C
Redline
1 pressure channel
Temperature ch. pos.
Redline
1 pressure channel
1 temperature channel
Redline
1 pressure channel
2 temperature channel
Français
EBI 12-T67x / EBI 12-T69x
Gamme de produits:
Conception:
Plage de mesure:
Précision:
±0,2 °C (-20 °C ... 0 °C)
±0,1 °C (0 °C ... +120 °C)
±0,05 °C (+120 °C ... +140 °C)
±0,1 °C (+140 °C ... +150 °C)
Precision Pressure Logger
EBI 12-TP 19x / EBI TP 29x
Gamme de produits:
Conception:
Plage de mesure:
0,1 ... 1,050 mbar
Précision:
±0,1 °C (0 °C ... +120 °C)
±0,05 °C (+120 °C ... +140 °C)
±0,1 °C (+140 °C ... +150 °C)
±0,25 mbar (0,1 mbar ... 50 mbar)
±5% v. MV (50 mbar ... 100 mbar)
±1 % FS (autonomie restante)
Pressure Logger
EBI 12-TP 22x / EBI TP 23x
Gamme de produits:
Conception:
pos.Plage de mesure:
1 ... 4,000 mbar
Précision:
±0,1 °C (0 °C ... +120 °C)
±0,05 °C (+120 °C ... +140 °C)
±0,1 °C (+140 °C ... +150 °C)
±10 mbar (50 mbar ... 150 mbar)
±10 mbar (2.050 mbar ... 2.250 mbar)
±10 mbar (3.000 mbar ... 3.250 mbar)
±20mbar (3.500 mbar ... 4.000 mbar)
±15 mbar (autonomie restante)
EBI 12-TP 32x
Gamme de produits:
Conception:
Plage de mesure: 0 °C ... +150 °C
1 ... 4,000 mbar
Précision:
±0,1 °C (0 °C ... +120 °C)
±0,05 °C (+120 °C ... +140 °C)
±0,1 °C (+140 °C ... +150 °C)
±10 mbar (50 mbar ... 150 mbar)
±10 mbar (2.050 mbar ... 2.250 mbar)
±10 mbar (3.000 mbar ... 3.250 mbar)
±20mbar (3.500 mbar ... 4.000 mbar)
±15 mbar (autonomie restante)
Redline
4 canaux, flexible
sondes à câble
1,2 mm de diamètre
-20 °C ... +150 °C
Redline
1 canal de pression
Température ch. pos.
0 °C ... +150 °C
Redline
1 canal de pression
Température ch.
0 °C ... +150 °C
Redline
1 pressure channel
2 temperature channel
55