Herunterladen Inhalt Inhalt Diese Seite drucken

Test Running; Service; Filterchange; Accessories - Dustcontrol S32000 Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für S32000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 17

Test Running

Check that the vacuum producer is correctly installed and
inlet and outlet connected to the duct system. Th e tubing
between the fi lter unit and vacuum producer must be free
from particles. Objects in the vacuum producer can cause
failure.
Check discharge arrangement. No leakage can be al-
lowed.

Service

If the system does not give full suction after fi lter clea-
ning, it is recommended that the fi ne fi lters are changed.
Use only original fi lters.
Th e condition of the fi lters can be checked by measuring
the pressure drop over the cleaned fi lters with a mano-

Filterchange

Th e fi lters should be changed at least once per year. Only
original fi lter is allowed. Use breathing protection during
the fi lter change. Do not expose unprotected persons to
harmful dust.
-
Turn off and lock the disconnect of the vacuum
producer.
-
Use breathing protection.
-
Lift off the top of the fi lter unit.
-
Lift out the fi lters and seal them in a plastic sack.
-
Lift in the new fi lters, and connect the top.

Accessories

Collecting sack
Widening schassis
Module ring
All manuals and user guides at all-guides.com
Art nr 4714
Art nr 7195
Art nr 4612
S 32000, S 34000, S 34000X, S 46000 - 15
Cleaning of the fi lters
Th e fi lters of the dust separator are cleaned automatically.
Th is is done at diff erent times, depending on
confi guration of the system.
When the fi lter is cleaned a number of very clear air pul-
ses, with a few seconds interval, should be heared.
meter (Part No 8283). If the manometer registers a value
higher than 3 - 4 kPa the fi lters should be changed.
Some time after the installation there should be a follow-
up check on all screws and nuts.
If the extracted dust is collected in a plastic bag, the bag
should be changed when the dust level is 5 cm under the
plastic fl ap at the bottom of the fi lter unit. Th e plastic
sack must be sealed when removed from the fi lter unit.
If the dust is collected in a container, it should be chan-
ged or emptied before it is completely full.
Filter Part No
S 32000
4292
S 34000
4292
S 34000X
4284
S 46000
4284
Cleaning accessories, hoses, valves and shutters can be found
in Dustcontrols catalogue.
Number
2
4
4
6
Part No 9065, 94160

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

S34000S34000xS46000

Inhaltsverzeichnis