By-alarm
01700.DE
• No. 3 switch-on modes for each Area (ON, INT, and
PAR)
• possibility of external activation with proximity reader
in 3 modes for each Area
Switch-on
• by User Telemanagement, guided by voice menu or
SMS via the By-phone and By-web apps
• via weekly programmable time switch in the 3 modes
for each Area
• weekly clock with 32 daily operations and exclusion
management
• possibility of switching on and off, inhibiting codes and
Clock
keyboards, activating macros
• timed activation and with active output status
• No. 16 telephone numbers for communications with
protocols:
- SIA for communications to SIA standard receivers
-CONTACT ID for communications to CONTACT
standard receivers
• voice synthesis module 01713.EN with voice protocol
Telephone
for automatic communications that allows sending all
the alarm and control functions of the control panel to
private users
• transmitter/receiver module 01706 that enables send-
ing all the protocols over a GSM network and, via
SMS text messages, all the alarm and control func-
tions of the control panel
• via keyboard with simplified menu with error manage-
ment
Programming
• via computer with interactive connection via the By-
alarm Manager software for Windows operating sys-
tems
• 13.8 Vdc 1.5 A actual total with low battery charge
Power supply unit
and mains voltage failure signalling
Battery that can be
• 12 Vdc 7 Ah or 12 Vdc 18 Ah flammability class UL94-
housed
HB
Ambient conditions
• -10..+40°C
Enclosure
• Dimensions: 322 x 350 x 115 mm. - Weight: 3.5 kg.
Degree of safety
• 2 (EN 50131-3, EN 50131-6)
Ambient class
• II (EN 50131-3, EN 50131-6)
INSTALLATION RULES
Installation should be carried out in compliance with the current regulations regard-
ing the installation of electrical equipment in the country where the products are
installed.
Wiring
For the wiring, it is necessary to use halogen-free shielded cables suitable for
installation with Category 1 power cables (U0 = 400 V). The VIMAR codes of
the connection cables to be used for the transmission bus RS485 and the wired
connection of the devices are the following:
• art. 01732 (2x0.22 mm
)
2
• art. 01733 (2x0.50 mm
+2x0.22 mm
2
• art. 01734 (2x0.50 mm
+4x0.22 mm
2
• art. 01735 (2x0.50 mm
+6x0.22 mm
2
• IMPORTANT: The cable shield must be connected only at the end of the control
panel or of the additional power supply and connected to the negative termi-
nal of the supply voltage. The connection cables for the By-alarm system are
compliant for routing with the power supply cables of the mains voltage; how-
ever, we recommend you to lay the connection cables in a dedicated raceway
and avoid laying in parallel with the power supply cables and particularly with
cables of inverters and loads such as pumps, burners, ballasts, motors, etc.,
especially for long distances.
• The wiring of the sensors/contacts to the inputs, both directly in the control
panel and in the expansion modules, must not exceed 100 m.
49401110A0 03 2011
)
2
)
2
)
2
CAUTION: We do not recommend connecting multiple contacts in series be-
cause you would lose the ability to distinguish the contact that may be open
or tampered with.
This recommendation applies all the more to sensors because, in addition to
managing alarm signalling, they also signal tampering and anti-masking (dou-
ble or triple input balancing) and this cannot occur if the devices are connected
in series on the same input.
• The wiring of the RS485 bus can be made with free topology and you can then
make all the relevant shunting, however it is recommended to make a direct
connection wherever possible.
• The maximum permissible length of the wiring is 600 m (the sum of all the
lengths of bus laid out).
• The isolator/repeater module art. 01711 lets you expand the RS485 bus to get
another 600 m of cable to use for the wiring.
Control panel earth connection
For the earth connection you need to use the specific terminal located under the
transformer by the connection of its mains power supply; the cover should also be
earthed, using the Faston terminal.
Caution: correct earthing protects the control panel and all its devices from faults
caused by electrical and atmospheric discharges and in particular ensures the in-
tegrity of the telecommunications network.
REGULATORY COMPLIANCE
EN 50131-3, EN 50131-6, EN 50131-10, EN 50136-2.
LV directive. EMC directive.
Standards EN 60950-1, EN 50130-4, EN 61000-6-3.
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces
of lead.
For all the details about installing the control panel 01700.DE, see the instal-
lation manual that can be downloaded from the website www.vimar.com.
For all the details about configuring the control panel 01700.DE, see the pro-
gramming manual that can be downloaded from the website www.vimar.com.
WEEE - Information for users
If the crossed-out bin symbol appears on the equipment or packaging, this means the product must not
be included with other general waste at the end of its working life. The user must take the worn product
to a sorted waste center, or return it to the retailer when purchasing a new one. Products for disposal can
be consigned free of charge (without any new purchase obligation) to retailers with a sales area of at least
400 m
, if they measure less than 25 cm. An efficient sorted waste collection for the environmentally friendly
2
disposal of the used device, or its subsequent recycling, helps avoid the potential negative effects on the
environment and people's health, and encourages the re-use and/or recycling of the construction materials.
EARTH
CONNECTION
Viale Vicenza, 14
36063 Marostica VI - Italy
www.vimar.com