Gate Control 20 Quick guide
Example:
Adding 2 user phone numbers, changing the activation time of output NO1 to
3 seconds, and setting output NO2 to bistable operating mode:
PWD=1111#TEL=+36301111111#TEL=+36202222222#REL1=3#REL2=FIX#
Response of the device to SMS commands
After receiving commands, the device will send response messages as follows:
Device response
Wrong password
Password changed
3 user(s) added
User removed
User not found to delete The phone number you want to delete was not found
Rel1 mode set OK
Invalid Rel1 time
Rel1 time OK
Input type OK
Intype error
Input sens. OK
Invalid input sens.
Report nr. OK
SMS limit OK
SMS limit=50!
No SMS limit
CMD error
Empty phonebook
Meaning
The provided password is invalid
The password has been changed successfully
3 phone numbers added successfully
Phone number deleted successfully
Output NO1 operating mode changed
The activation time specified for output NO1 is
invalid
Output
NO1
activation
successfully
Input type changed successfully
Input type error, invalid parameter
Input sensitivity changed successfully
Input sensitivity error, invalid value
The phone number for SMS sending/forwarding
changed successfully
SMS limitation value changed successfully
Invalid SMS limitation value, therefore set to 50
SMS limitation disabled
Command typing error
No users/phone numbers found
7
time
has
been
set