Z*C
Entstörfilter (Ferritkern)
*
Optionales
#
Bauseitig zu liefern
Übersetzung des Texts des Elektroschaltplans
Englisch
(1) Main power connection
For preferential kWh rate power
supply
Normal kWh rate power supply
Only for preferential kWh rate
power supply with separate
normal kWh rate power supply
Only for preferential kWh rate
power supply without separate
normal kWh rate power supply
Preferential kWh rate power
supply contact: 16 V DC
detection (voltage supplied by
PCB)
SWB
(2) Power supply BUH
BLK
BLU
BRN
GRY
Only for combined 1F BUH/
compressor power supply (3/6
kW)
Only for combined 3F BUH/
compressor power supply (6/9
kW)
Only for dual cable power supply Nur für Stromversorgung mit
Only for single cable power
supply
Only for split 1F BUH/1F
compressor power supply (3/6
kW)
Only for split 3F BUH/1F
compressor power supply (6/9
kW)
SWB
YLW/GRN
(3) User interface
Only for remote user interface
SWB
(4) Drain pump
SWB
(5) Ext. indoor ambient thermistor (5) Externer
SWB
(6) Field supplied options
12 V DC pulse detection (voltage
supplied by PCB)
230 V AC supplied by PCB
EGSAH/X06+10DA9W(G)
Daikin Altherma 3 GEO
4P569811-1B – 2019.09
Übersetzung
(1) Hauptstromanschluss
Für Wärmepumpentarif-
Netzanschluss
Normaltarif-Netzanschluss
Nur für Wärmepumpentarif-
Stromversorgung mit separatem
Normaltarif-Netzanschluss
Nur für Wärmepumpentarif-
Stromversorgung ohne
separaten Normaltarif-
Netzanschluss
Wärmepumpentarif-
Netzanschlusskontakt: 16 V DC-
Erkennung
(Spannungsversorgung durch
Platine)
Schaltkasten
(2) Stromversorgung für
Reserveheizung
Schwarz
Blau
Braun
Grau
Nur für kombinierte 1F-
Reserveheizung-/Verdichter-
Stromversorgung (3/6 kW)
Nur für kombinierte 3F-
Reserveheizung-/Verdichter-
Stromversorgung (6/9 kW)
zwei Kabeln
Nur für Stromversorgung mit
einem Kabel
Nur für geteilte 1F-
Reserveheizungs-/1F-Verdichter-
Stromversorgung (3/6 kW)
Nur für geteilte 3F-
Reserveheizung-/1F-Verdichter-
Stromversorgung (6/9 kW)
Schaltkasten
Gelb/grün
(3) Bedieneinheit
Nur für Fernbedienungs-
Bedieneinheit
Schaltkasten
(4) Ablaufpumpe
Schaltkasten
Innentemperaturfühler
Schaltkasten
(6) Bauseitig gelieferte Optionen
12 V Gleichstrom
Impulserkennung (Spannung
wird durch Platine geliefert)
230 V Wechselstrom
Spannungsversorgung durch
Platine
Englisch
Continuous
DHW pump
DHW pump output
Electrical meters
For safety thermostat
Inrush
Max. load
Normally closed
Normally open
Safety thermostat contact: 16 V
DC detection (voltage supplied
by PCB)
Shut-off valve
SWB
(7) Option PCBs
Alarm output
Changeover to ext. heat source
Max. load
Min. load
Only for demand PCB option
Only for digital I/O PCB option
Options: ext. heat source output,
alarm output
Options: On/OFF output
Power limitation digital inputs: 12
V DC / 12 mA detection (voltage
supplied by PCB)
Space C/H On/OFF output
SWB
(8) External On/OFF thermostats
and heat pump convector
Additional LWT zone
Main LWT zone
Only for external sensor (floor/
ambient)
Only for heat pump convector
Only for wired On/OFF
thermostat
Only for wireless On/OFF
thermostat
(9) Current sensors
SWB
(10) Brine pressure loss
detection
SWB
With pressure loss detection
Without pressure loss detection
9 Technische Daten
Übersetzung
Dauerstrom
Brauchwasserpumpe
Auslass der
Brauchwasserpumpe
Stromzähler
Für Sicherheitsthermostat
Einschaltstrom
Maximale Belastung
Öffner
Schließer
Sicherheitsthermostat-Kontakt:
16 V Gleichstrom-Erkennung
(Spannungsversorgung durch
Platine)
Absperrventil
Schaltkasten
(7) Optionen-Platinen
Alarmausgang
Umschalter zur externen
Wärmequelle
Maximale Belastung
Minimale Belastung
Nur für optionale Zusatz-Platine
Nur für die optionale digitale E/A-
Platine
Optionen: externe
Wärmequellenausgabe,
Alarmausgang
Optionen: Ausgang für EIN/AUS
Digitaleingänge für
Leistungsbeschränkung:
12 V Gleichspannung / 12 mA
Demodulation
(Spannungsversorgung durch
Platine)
Ausgang für Raumkühlung/-
heizung EIN/AUS
Schaltkasten
(8) Externer Thermostat/
Wärmepumpenkonvektor EIN/
AUS
Zusatz-Vorlauftemperaturzone
Haupt-Vorlauftemperaturzone
Nur für externen Fühler (Boden
oder Umgebungstemperatur)
Nur für Wärmepumpen-
Konvektor
Nur für verkabelten EIN/AUS-
Thermostat
Nur für kabellosen EIN/AUS-
Thermostat
(9) Stromsensoren
Schaltkasten
(10) Sole-Druckverlusterkennung
Schaltkasten
Mit Druckverlusterkennung
Ohne Druckverlusterkennung
Installationsanleitung