Herunterladen Diese Seite drucken

Konig & Meyer 22150 Serie Bedienunganleitung Seite 3

Deckenstativ

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

22150/22160 Ceiling mount
Hanging microphone holding system - variable height adjustment
Once attached to the ceiling it can be quickly attached and taken down any time
Perfect for studios and rehearsal rooms
Thank you for choosing this product. The instructions provide information to all
of the important setup and handling steps. We recommend you keep these
instructions for future reference.
PROFILE
Model: 22150-300-55 = 3/8"-thread (610-1120 mm)
Model:
22150-500-55 = including 5/8"- thread adapter
Model:
22160-300-55 = 3/8"-thread (860-1560 mm)
Model:
22160-500-55 = including 5/8"- thread adapter
Ceiling flange: Steel plate ø 105 x 4 mm with 4 drill holes ø 6.5/80 mm;
Ceiling flange:
with base tube supports ø 20 mm
STAND 22150: Base tube ø 20 x 550 mm, Extension tube ø 15 x 550 mm,
STAND 22150:
Variable height adjustment: 610 – 1120 mm
STAND 22160: Base tube ø 20 x 800 mm, Extension tube ø 15 x 750 mm,
STAND 22160:
Variable height adjustment: 860 – 1560 mm
STAND 22160:
quick adjustment through the non-slip clutch;
STAND 22160:
Thread (3/8"; 5/8") for the microphone or boom arm
Material: Plate, support, tube: Steel, powder coating
Material:
Threads: Steel, galvanized
Material:
Clutch, sleeve, brake, cable holder: PA
Surfaces: powder coated, black
Data: Weight bearing load: max 1 kg, exclusively for microphones,
Data:
Box 1010 x 100 x 50 mm, 0.3 kg
Data:
Weight 22150: net. 1.1 kg - 22160: net. 1.35 kg
Particulars: The tube combination may only be mounted
Particulars:
vertically, otherwise damage to the stand is possible
SAFETY NOTES
Operational safety is largely dependent on:
a. LOAD BEARING WEIGHT: exclusively microphones up to 1 kg
b. HANDLING correct mounting and use
c. Ceiling: must be load bearing and even.
d. EXTERNAL CIRCUMSTANCES: protect against lateral
d.
forces such as wind, being bumped into and the public etc...
- First, conduct a visual inspection to ensure that all the parts are included
-
and to the extent possible are in working order.
- Damaged parts may not i.e. may no longer be used
- Not suitable for outdoors or moist rooms
- Please refer to local mounting instructions
-
(May possibly deviate from the examples provided in Section 2.3)
- Use 4 screws/anchors for the ceiling mount
- Only use trained technicians to install the system
- Only mount on suitable ceilings with the corresponding
-
assembly material (not included in the delivery)
- Ceilings, that are too weak or have electrical and water conduits are not
-
suitable. In case of doubt, consult a qualified technician.
- Check the stability of the installation regularly.
- Tighten the threads, but do not over-tighten (manual tightening is
-
sufficient) Check that the connection is tight on a routine basis,
-
tighten if needed.
- To care for the product, use a damp cloth and a non-abrasive
-
cleaning agent.
SETUP & FUNCTIONS
A. CEILING FLANGE
1. Select suitable ceiling and mounting materials
1.
EXAMPLE- Concrete ceiling: e.g. Bolt-Anchor M6 x 75 mm
1.
Position plate, mark the drill holes.
2. Drill four holes (ø 6 mm) and blow out the holes
3. Hammer in the bolt anchor, place the flange
4. Place the U disks and tighten the nuts
B. TUBE COMBINATION
5. Place the base tube in the support
6. Adjust the drill holes and supports
7. Screw in the raised head screw as far as it will go
HEIGHT
8.A - Hold the extension tube while the tension handle is loosened
9.A
- Adjust the extension tube to the desired height
8.B - Tighten the tension handle (tight, not too tight)
C. ATTACH MICROPHONE
10 - The microphone connector threads are either 3/8" or 5/8" depending
10 -
on the model and come with a knurled washer
11 - The Ceiling mounts come with a cable clamp, which
11 -
can be clipped to the base tube or placed anywhere on the tube
COMMENTS REGARDING THE USE OF BOOM ARMS
Ceiling mounts 22150 and 22160 are not equipped with boom arms.
The use of a swivel arm is an option. We recommend, however, that it
not be extended too far, to keep the pull to a minimum on the extended
arm and the vertical tube combination.
22150-300/500-55 Rev.05 / 22160-300/500-55 Rev.06/08 03-79-103-00 7/20
Accessory bag
KÖNIG & MEYER GmbH & Co. KG
Kiesweg 2, 97877 Wertheim, www.k-m.de

Werbung

loading

Diese Anleitung auch für:

22160 serie22150-300-5522150-500-5522160-300-5522160-500-55